MECHANICAL-PROPERTIES OF TRABECULAR BONE - DEPENDENCY ON STRAIN RATE

被引:121
作者
LINDE, F
NORGAARD, P
HVID, I
ODGAARD, A
SOBALLE, K
机构
[1] Biomechanics Laboratory, Department of Orthopaedic Surgery, Aarhus University Hospital, DK-8200 Århus N
关键词
D O I
10.1016/0021-9290(91)90305-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The effect of strain rate (epsilon) and apparent density (rho) on stiffness (E), strength (sigma-u), and ultimate strain (epsilon-u) was studied in 60 human trabecular bone specimens from the proximal tibia. Testing was performed by uniaxial compression to 5% specimen strain. Six different strain rates were used: 0.0001, 0.001, 0.01, 0.1, 1, and 10 s-1. Apparent density ranged between 0.23 and 0.59 g cm-3. Linear and non-linear regression analyses using strength, stiffness and ultimate strain as dependent variables (Y) and strain rate and apparent density as independent variables were performed using the following models: Y = a-rho-b-epsilon-c, Y = rho-b(a + c-epsilon; Y = (a + b-rho)epsilon-c, Y = a-rho-2-epsilon-c, E = a-rho-3-epsilon-c. The variations of strength and stiffness were explained equally well by the linear and the power function relationship to strain rate. The exponent was 0.07 in the power function relationship between strength and strain rate and 0.05 between stiffness and strain rate. The variation of ultimate strain was explained best using a power function relationship to strain rate (exponent = 0.03). The variation of strength and stiffness was explained equally well by the linear, power function and quadratic relationship to apparent density. The cubic relationship between stiffness and apparent density showed a less good fit. Ultimate strain varied independently of apparent density.
引用
收藏
页码:803 / 809
页数:7
相关论文
共 43 条
[1]   THE MECHANICAL-PROPERTIES OF CELLULAR SOLIDS [J].
ASHBY, MF .
METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1983, 14 (09) :1755-1769
[2]   ANATOMICAL VARIATION OF ORTHOTROPIC ELASTIC-MODULI OF THE PROXIMAL HUMAN TIBIA [J].
ASHMAN, RB ;
RHO, JY ;
TURNER, CH .
JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) :895-900
[3]   ELASTIC PROPERTIES OF CANCELLOUS BONE - MEASUREMENT BY AN ULTRASONIC TECHNIQUE [J].
ASHMAN, RB ;
CORIN, JD ;
TURNER, CH .
JOURNAL OF BIOMECHANICS, 1987, 20 (10) :979-986
[4]   VARIATIONS IN STRENGTH AND STRUCTURE OF CANCELLOUS BONE AT KNEE [J].
BEHRENS, JC ;
WALKER, PS ;
SHOJI, H .
JOURNAL OF BIOMECHANICS, 1974, 7 (03) :201-207
[5]  
Brear K, 1988, Eng Med, V17, P163, DOI 10.1243/EMED_JOUR_1988_017_043_02
[6]   MECHANICAL PROPERTY DISTRIBUTIONS IN THE CANCELLOUS BONE OF THE HUMAN PROXIMAL FEMUR [J].
BROWN, TD ;
FERGUSON, AB .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03) :429-437
[7]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[8]  
CASSIDY JJ, 1985, T ORS, V10, P354
[9]  
COOK M, 1945, J I MET, V71, P371
[10]  
Currey J D, 1986, Eng Med, V15, P153, DOI 10.1243/EMED_JOUR_1986_015_039_02