摘要
This report presents the results of a study designed to verify the influence of lens opacities on the visual field indices. Four age-matched groups of subjects were considered: Healthy volunteers, glaucomatous patients without lens opacities, cataractous patients without glaucoma and glaucomatous patients with lens opacities. The quantification of lens opacities was performed with the Lens Opacity Meter 701 instrument. The visual field indices were obtained automatically from the G1 program of the Octopus system. The statistical analysis of the results (coefficient of correlation) has shown that only the visual field indices that correspond to uniform and diffuse loss of light sensitivity were influenced by the presence of cataract. On the contrary, the visual field indices that indicate local irregularities of the threshold were not significantly influenced by the presence of lens opacities. © 1990 S. Karger AG, Basel.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 16 条
[1]  
BEBIE H, 1985, AUTOMATIC PERIMETRY, P147
[2]   INVIVO MEASUREMENT OF HUMAN LENS AGING USING THE LENS OPACITY METER [J].
COSTAGLIOLA, C ;
ULIANO, G ;
RINALDI, E ;
TRAPANESE, A ;
RUSSO, V ;
CAMERA, A ;
SCIBELLI, G .
OPHTHALMOLOGICA, 1989, 199 (04) :158-161
[3]   QUANTIFICATION AND MEASUREMENT OF HUMAN LENS OPACITIES USING THE LENS OPACITY METER [J].
COSTAGLIOLA, C ;
IULIANO, G ;
MARINO, E ;
PAOLERCIO, F ;
TRAPANESE, A ;
APPONIBATTINI, G .
OPHTHALMOLOGICA, 1990, 201 (01) :45-48
[4]  
COSTAGLIOLA C, IN PRESS INFLUENCE H, V2
[5]  
COSTAGLIOLA C, 1989, 3RD EUR M OCT US SOC
[6]  
CROWELY FJ, 1967, BASIC FACTS STATISTI, P1
[7]   LENS OPACITY METER - A NEW INSTRUMENT TO QUANTIFY LENS OPACITY [J].
FLAMMER, J ;
BEBIE, H .
OPHTHALMOLOGICA, 1987, 195 (02) :69-72
[8]   DIFFERENTIAL LIGHT THRESHOLD IN AUTOMATED STATIC PERIMETRY - FACTORS INFLUENCING SHORT-TERM FLUCTUATION [J].
FLAMMER, J ;
DRANCE, SM ;
FANKHAUSER, F ;
AUGUSTINY, L .
ARCHIVES OF OPHTHALMOLOGY, 1984, 102 (06) :876-879
[9]  
FLAMMER J, 1985, INVEST OPHTH VIS SCI, V26, P176
[10]   THE CONCEPT OF VISUAL-FIELD INDEXES [J].
FLAMMER, J .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1986, 224 (05) :389-392