CLINICAL-TRIALS OF AN INTRAVENOUS OXYGENATOR IN PATIENTS WITH ADULT RESPIRATORY-DISTRESS SYNDROME

被引:46
作者
HIGH, KM
SNIDER, MT
RICHARD, R
RUSSELL, GB
STENE, JK
CAMPBELL, DB
AUFIERO, TX
THIEME, GA
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,COLL MED,DEPT SURG,HERSHEY,PA 17033
[2] PENN STATE UNIV,MILTON S HERSHEY MED CTR,COLL MED,DEPT RADIOL,HERSHEY,PA 17033
关键词
LUNGS; ADULT RESPIRATORY DISTRESS SYNDROME; MEMBRANE LUNG;
D O I
10.1097/00000542-199211000-00004
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In patients with severe adult respiratory distress syndrome, mechanical ventilation may not be able to ensure gas exchange sufficient to sustain life. We report the use of an intravenous oxygenator (IVOX) in five patients who were suffering from severe adult respiratory distress syndrome as a result of aspiration, fat embolism, or pneumonia. IVOX was used in an attempt to provide supplemental transfer Of CO2 and O2 and thereby reduce O2 toxicity and barotrauma. All patients were tracheally intubated, sedated, and chemically paralyzed and had a Pa(O2) < 60 mmHg when the lungs were ventilated with an FI(O2) = 1.0 and a positive end expiratory pressure of greater-than-or-equal-to 5 cmH2O. The right common femoral vein was located surgically, and the patient was systemically anticoagulated with heparin. A hollow introducer tube was inserted into the right common femoral vein, and the furled IVOX was passed into the inferior vena cava and advanced until the tip was in the lower portion of the superior vena cava. IVOX use ranged from 2 h to 4 days. In this group of patients, IVOX gas exchange ranged from 21 to 87 ml X min-1 of CO2 and from 28 to 85 ml X min-1 of O2. One of the five patients survived and was discharged from the hospital. The IVOX transferred up to 28% of metabolic gas-exchange requirements. One patient with a small vena cava showed signs of caval obstruction. Three other patients demonstrated signs of a septic syndrome after the device was inserted. In the patient who survived, the IVOX did not appear to play a significant role in his outcome. Clinical considerations and factors limiting the use of the IVOX are presented. Because of gas-exchange limitations, design alterations to the IVOX may be required.
引用
收藏
页码:856 / 863
页数:8
相关论文
共 28 条
  • [1] ARMENGOL J, 1989, BR J ANAESTH S, V63, pS16
  • [2] Bagley B., 1991, ASAIO T, V37, pM413
  • [3] BALK RA, 1989, CRIT CARE CLIN, V5, P1
  • [4] TREATMENT OF ACUTE RESPIRATORY-FAILURE BY EXTRACORPOREAL CARBON-DIOXIDE ELIMINATION PERFORMED WITH A SURFACE HEPARINIZED ARTIFICIAL LUNG
    BINDSLEV, L
    EKLUND, J
    NORLANDER, O
    SWEDENBORG, J
    OLSSON, P
    NILSSON, E
    LARM, O
    GOUDA, I
    MALMBERG, A
    SCHOLANDER, E
    [J]. ANESTHESIOLOGY, 1987, 67 (01) : 117 - 120
  • [5] BUHLMANN AA, 1984, DECOMPRESSION DECOMP, P7
  • [6] COX C S JR, 1991, Perfusion (London), V6, P291, DOI 10.1177/026765919100600409
  • [7] STUDIES OF CONGENITAL HEART DISEASE .2. THE PRESSURE AND OXYGEN CONTENT OF BLOOD IN THE RIGHT AURICLE, RIGHT VENTRICLE, AND PULMONARY ARTERY IN CONTROL PATIENTS, WITH OBSERVATIONS ON THE OXYGEN SATURATION AND SOURCE OF PULMONARY CAPILLARY BLOOD
    DEXTER, L
    HAYNES, FW
    BURWELL, CS
    EPPINGER, EC
    SAGERSON, RP
    EVANS, JM
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1947, 26 (03) : 554 - 560
  • [8] FRISK C, 1989, BRIT J ANAESTH, V63, pS115
  • [9] GATTINONI L, 1980, LANCET, V2, P292
  • [10] Jurmann M J, 1992, ASAIO J, V38, P120, DOI 10.1097/00002480-199204000-00011