POLYETHYLENE WEAR IN CEMENTED METAL-BACKED ACETABULAR CUPS

被引:116
作者
CATES, HE [1 ]
FARIS, PM [1 ]
KEATING, EM [1 ]
RITTER, MA [1 ]
机构
[1] CTR HIP & KNEE SURG, 1199 HADLEY RD, MOORESVILLE, IN 46158 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1993年 / 75卷 / 02期
关键词
D O I
10.1302/0301-620X.75B2.8444945
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The mean volumetric wear rate was 66.2 mm3/yr in the metal-backed sockets and 48.2 mm3/yr in the polyethylene sockets (p = 0.0002). The addition of metal backing to a cemented acetabular cup therefore resulted in a 37% increase in mean polyethylene wear rates which may partially explain the higher failure rate of cemented metal-backed cups. Linear regression analysis also implicated increased follow-up time (log), gross acetabular migration, metal backing and male gender in increasing polyethylene wear. We advocate the use of an all-polyethylene cup in cemented total hip arthroplasty. The increased polyethylene wear must also cause concern about the wear rate of uncemented metal-backed acetabular sockets.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 38 条
  • [1] METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS
    AGINS, HJ
    ALCOCK, NW
    BANSAL, M
    SALVATI, EA
    WILSON, PD
    PELLICCI, PM
    BULLOUGH, PG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) : 347 - 356
  • [2] Bartel D L, 1983, Hip, P229
  • [3] THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT
    BARTEL, DL
    BICKNELL, VL
    WRIGHT, TM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) : 1041 - 1051
  • [4] METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT
    BLACK, J
    SHERK, H
    BONINI, J
    ROSTOKER, WR
    SCHAJOWICZ, F
    GALANTE, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) : 126 - 130
  • [5] Carter D R, 1983, Hip, P216
  • [6] STRESS DISTRIBUTIONS IN THE ACETABULAR REGION .2. EFFECTS OF CEMENT THICKNESS AND METAL BACKING OF THE TOTAL HIP ACETABULAR COMPONENT
    CARTER, DR
    VASU, R
    HARRIS, WH
    [J]. JOURNAL OF BIOMECHANICS, 1982, 15 (03) : 165 - 170
  • [7] OPTIMUM SIZE OF PROSTHETIC HEADS IN RELATION TO WEAR OF PLASTIC SOCKETS IN TOTAL REPLACEMENT OF HIP
    CHARNLEY, J
    KAMANGAR, A
    LONGFIELD, MD
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1969, 7 (01): : 31 - +
  • [8] CHARNLEY J, 1975, CLIN ORTHOP RELAT R, V112, P170
  • [9] Charnley J, 1973, CLIN ORTHOP RELAT R, V95, P9
  • [10] CLARKE IC, 1976, CLIN ORTHOP RELAT R, P126