COMPARISON OF THE GC/MS ION TRAPPING TECHNIQUE WITH GC-FTIR FOR THE IDENTIFICATION OF STIMULANTS IN DRUG-TESTING

被引:14
作者
DEJONG, EG
KEIZERS, S
MAES, RAA
机构
[1] Netherlands Institute for Drugs and Doping Research, University of Utrecht, Utrecht, 3521 GE
关键词
D O I
10.1093/jat/14.2.127
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Identification of banned stimulants in the urine of athletes is typically performed by gas chromatography with electron impact mass spectrometry (GC-EIMS). Derivatization is usually used to improve the chromatographic properties and to produce unique mass spectra for closely related compounds. Both gas chromatography with chemical ionization mass spectrometry (GC-CIMS) and gas chromatography with Fourier transform infrared spectroscopy (GC-FTIR) were compared for three test mixtures of stimulants. Both techniques were capable of supplying the necessary information for conclusive confirmation. However, the CI option on the ion trap mass detector (ITD) offers the most sensitive and fastest way for the confirmation of positive samples with detection limits of 110 ng. The GC-FTIR is from a chemometrics point of view more specific but needs 2575 ng for a reliable spectrum. © 1990 Oxford University Press.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 12 条
[1]   A DISCUSSION OF EPHEDRINE ANALYSIS [J].
ASSELIN, WM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1987, 11 (02) :87-88
[3]   N-TRIFLUOROACETYL-O-TRIMETHYLSILYL-PHENOLALKYLAMINES - PREPARATION AND MASS SPECIFIC GAS-CHROMATOGRAPHIC ESTIMATION [J].
DONIKE, M .
JOURNAL OF CHROMATOGRAPHY, 1975, 103 (01) :91-112
[4]   CONTROL OF TRIMETHYLSILYLATION POTENTIAL AND TRIMETHYLSILYLATION CAPACITY BY USE OF COLOR INDICATORS [J].
DONIKE, M .
JOURNAL OF CHROMATOGRAPHY, 1975, 115 (02) :591-595
[5]   ACYLATION WITH BIS(ACYLAMIDES) - N-METHYL-BIS(TRIFLUOROACETAMIDE) AND BIS(TRIFLUOROACETAMIDE), 2 NEW REAGENTS FOR TRIFLUOROACETYLATION [J].
DONIKE, M .
JOURNAL OF CHROMATOGRAPHY, 1973, 78 (02) :273-279
[6]   IDENTIFICATION OF AMPHETAMINE ISOMERS BY GC IR MS [J].
DUNCAN, W ;
SOINE, WH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (10) :521-526
[7]   THE HYPHENATION OF CHROMATOGRAPHY AND FT-IR SPECTROMETRY [J].
GRIFFITHS, PR ;
PENTONEY, SL ;
GIORGETTI, A ;
SHAFER, KH .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :1349-&
[8]  
LIM HK, 1988, SPECTRA, V2, P10
[9]   SERIALLY INTERFACED GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETER ION TRAP MASS-SPECTROMETER SYSTEM [J].
OLSON, ES ;
DIEHL, JW .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :443-448
[10]   THEORETICAL LIMITATIONS OF GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC IDENTIFICATION OF MULTICOMPONENT MIXTURES [J].
ROSENTHAL, D .