MUTAGENICITY OF AH26 IN AN IN-VITRO MAMMALIAN-CELL MUTATION ASSAY

被引:23
作者
SCHWEIKL, H
SCHMALZ, G
STIMMELMAYR, H
BEY, B
机构
关键词
D O I
10.1016/S0099-2399(06)80825-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The mutagenic activity of the root canal sealer AH26 was tested in the V79/hprt mammalian cell mutation assay, AH26 was mixed and eluted immediately after mixing or after setting times of 24 h or 7 days, Different amounts of dimethyl sulfoxide or physiological saline eluates were then tested for mutagenicity, Eluates of mixed AH26 were toxic and mutagenic, and both effects strongly depended on the setting time, The number of mutants after exposure to eluates of unset AH26 was enhanced similar to 7- to 10-fold. However, the mutagenic activity of the mixed material was clearly reduced after a setting time of 1 wk, Physiological saline eluates of the mixed AH26 were toxic at higher doses, but were not found to be mutagenic, Dimethyl sulfoxide eluates of the liquid component of AH26 elicited mutagenic effects similar to the freshly mixed material; eluates made in physiological saline were barely mutagenic at a 10-fold higher concentration, In accordance with recommendations of international guidelines, the V79/hprt mammalian cell mutation assay will be routinely used for the evaluation of the mutagenicity of dental materials in further investigations.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 12 条
[1]  
Gettleman, Messer, ElDeeb, Adhesion of sealer cements to dentin with and without the smear layer, J Endodon, 17, pp. 15-20, (1991)
[2]  
Sleder, Ludlow, Bohacek, Long-term sealing ability of a calcium hydroxide sealer, J Endodon, 17, pp. 541-543, (1991)
[3]  
Spangberg, Langeland, Biologic effects of dental materials. I. Toxicity of root canal filling materials on HeLa cells in vitro, Oral Surg, 35, pp. 402-414, (1973)
[4]  
Molloy, Goldman, White, Kabani, Comparative tissue tolerance of a new endodontic sealer, Oral Surg Oral Med Oral Pathol, 73, pp. 490-493, (1992)
[5]  
Pascon, Leonardo, Safavi, Langeland, Tissue reaction to endodontic materials: methods, criteria, assessment, and observations, Oral Surg Oral Med Oral Pathol, 72, pp. 222-237, (1991)
[6]  
Orstavik, Mjor, Usage test of four endodontic sealers in Macaca fascicularis monkeys, Oral Surg Oral Med Oral Pathol, 73, pp. 337-344, (1992)
[7]  
Orstavik, Hongslo, Mutagenicity of endodontic sealers, Biomaterials, 6, pp. 129-132, (1985)
[8]  
Schweikl, Schmalz, Evaluation of the mutagenic potential of a root canal sealer using the Salmonella/microsome assay, Journal of Materials Science: Materials in Medicine, 2, pp. 181-185, (1990)
[9]  
International Organization for Standardization, Biological evaluation of medical devices. Part 3. Tests for genotoxicity, carcinogenicity and reproductive toxicity, (1992)
[10]  
Kanematsu, Nakamine, Fukuta, Yasada, Kurenuma, Shibata, Mutagenicity of cadmium, platinum and rhodium compounds in cultured mammalian cells, Gifu Shika Gakki Zasshi, 17, pp. 575-581, (1990)