IONOPHORE/IONOMER FILMS ON GLASSY-CARBON ELECTRODES FOR ACCUMULATION VOLTAMMETRY - INVESTIGATION OF A LEAD(II) IONOPHORE

被引:9
作者
ARRIGAN, DWM
SVEHLA, G
ALDERMAN, J
LANE, WA
机构
[1] NATL UNIV IRELAND UNIV COLL CORK,DEPT CHEM,CORK,CORK,IRELAND
[2] NATL UNIV IRELAND UNIV COLL CORK,NATL MICROELECTR RES CTR,CORK,CORK,IRELAND
关键词
LEAD(II) IONOPHORE; METHYLENEBIS(N; N-DIISOBUTYLDITHIOCARBAMATE); IONOMER; ACCUMULATION; VOLTAMMETRY; MODIFIED ELECTRODE;
D O I
10.1039/an9941900287
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of ionophores in voltammetry with modified glassy carbon (GC) electrodes is described. A lead(II) ionophore, methylenebis(N,N-diisobutyldithiocarbamate) was dissolved in a solution containing 0.1% Nafion, and this mixture was applied to the GC electrode. Solvent evaporation gave the GC-Nafion-ionophore modified electrode. The composition of the film coating was studied with respect to the mass of Nafion and amount of ionophore; the best composition was found to comprise 20 mu g Nafion and 10 nmol ionophore. Accumulation of lead(II) from 0.1 mol l(-1) acetate buffer (pH 4) followed by voltammetry gave a quasi-reversible reduction peak at about -0.85 V (versus SCE), with half-wave potential, E(1/2) = -0.57 V and peak-to-peak separation, Delta E(p) = 0.51 V. This reduction potential is 0.25 V more negative than the reduction potential in the absence of the ionophore where E(1/2) = -0.48 V and Delta E(p) = 0.14 V. Accumulation of 1 X 10(-5) mol l(-1) Iead(II) for 60 s at the GC-Nafion-ionophore modified electrode gave a lead(II) surface coverage of 1.3 X 10(-9) mol cm(-2). The film exhibited thin-film voltammetric behaviour. Detection of lead(II) down to 1 X 10(-7) mol l(-1) with a 600 s accumulation time was possible. The effects of preconcentration time and solution composition were evaluated. The accumulation process appears to consist of two steps: ion exchange followed by complexation in the film.
引用
收藏
页码:287 / 292
页数:6
相关论文
共 22 条
[11]   THE EFFECT OF COMPLEXATION EQUILIBRIA ON THE RESPONSE OF CHEMICALLY MODIFIED ELECTRODES FOR THE DETERMINATION OF SILVER [J].
LABUDA, J ;
VANICKOVA, M .
ELECTROANALYSIS, 1993, 5 (02) :141-144
[12]  
MARTIN CR, 1981, ANAL CHEM, V53, P904
[13]  
Morf WE, 1981, STUDIES ANALYICAL CH, V2
[14]  
MURRAY RW, 1984, ELECTROANAL CHEM, V13, P191
[15]   CALIXARENE-BASED POTENTIOMETRIC ION-SELECTIVE ELECTRODES FOR SILVER [J].
OCONNOR, KM ;
SVEHLA, G ;
HARRIS, SJ ;
MCKERVEY, MA .
TALANTA, 1992, 39 (11) :1549-1554
[16]  
PORTER MD, 1992, ANAL CHEM, V64, pR79
[17]   PRECONCENTRATION AND DETERMINATION OF LEAD(II) AT CROWN ETHER AND CRYPTAND CONTAINING CHEMICALLY MODIFIED ELECTRODES [J].
PRABHU, SV ;
BALDWIN, RP ;
KRYGER, L .
ELECTROANALYSIS, 1989, 1 (01) :13-21
[18]   POTENTIOMETRIC ION-SELECTIVE, GAS-SELECTIVE, AND BIOSELECTIVE MEMBRANE ELECTRODES [J].
PRANITIS, DM ;
TELTINGDIAZ, M ;
MEYERHOFF, ME .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (03) :163-186
[19]   DIRECT EVIDENCE FOR CHEMICALLY DISTINCT REGIONS WITHIN NAFION FILMS ON ELECTRODES [J].
VINING, WJ ;
MEYER, TJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 237 (02) :191-208
[20]   PRECONCENTRATION AND VOLTAMMETRIC MEASUREMENT OF MERCURY WITH A CROWN-ETHER MODIFIED CARBON-PASTE ELECTRODE [J].
WANG, J ;