RP-IPC WITH A LACTIC-ACID MODIFIED ELUENT FOR SEPARATION AND DETERMINATION OF LANTHANIDE IONS

被引:17
作者
VERAAVILA, LE
CAMACHO, E
机构
[1] Analytical Chemistry Department, Facultad de Quirnica Universidad Nacional Autonóma de México, 04510 México, D.F.
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1992年 / 15卷 / 05期
关键词
D O I
10.1080/10826079208018838
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A modified method for the separation and determination of Rare Earth Elements in solution was developed. Lanthanide ions were separated by Reversed-Phase Ion Pair Chromatography using a mobile phase gradient of pH and lactic acid concentration. A post-column reaction with 4-(2 pyridyl)azo resorcinol was carried out for the spectrophotometric detection of solutes. The derivatizing reagent composition was optimized for good solute sensitivity and long-term reagent stability. Method limitations due to unadequate instrumentation are presented and discussed.
引用
收藏
页码:835 / 850
页数:16
相关论文
共 17 条
[1]   DYNAMIC CHROMATOGRAPHIC SYSTEMS FOR THE DETERMINATION OF RARE-EARTHS AND THORIUM IN SAMPLES FROM URANIUM ORE REFINING PROCESSES [J].
BARKLEY, DJ ;
BLANCHETTE, M ;
CASSIDY, RM ;
ELCHUK, S .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2222-2226
[2]   DYNAMIC ION-EXCHANGE CHROMATOGRAPHY FOR THE DETERMINATION OF NUMBER OF FISSIONS IN URANIUM-DIOXIDE FUELS [J].
CASSIDY, RM ;
ELCHUK, S ;
ELLIOT, NL ;
GREEN, LW ;
KNIGHT, CH ;
RECOSKIE, BM .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1181-1186
[3]   TRACE ENRICHMENT METHODS FOR THE DETERMINATION OF METAL-IONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CASSIDY, RM ;
ELCHUK, S .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1980, 18 (05) :217-223
[4]   DYNAMICALLY COATED COLUMNS FOR THE SEPARATION OF METAL-IONS AND ANIONS BY ION CHROMATOGRAPHY [J].
CASSIDY, RM ;
ELCHUK, S .
ANALYTICAL CHEMISTRY, 1982, 54 (09) :1558-1563
[5]  
DELREY ME, 1987, J LIQ CHROMATOGR, V10, P2911
[6]   SEPARATION OF SOME RARE-EARTHS AND TRANSPLUTONIUM ELEMENTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON OSTION CATION EXCHANGER [J].
DUFEK, P ;
VOBECKY, M ;
HOLIK, J ;
VALASEK, J .
JOURNAL OF CHROMATOGRAPHY, 1988, 435 (01) :249-252
[7]   SEPARATION OF THE LANTHANIDES ON HIGH-EFFICIENCY BONDED PHASES AND CONVENTIONAL ION-EXCHANGE RESINS [J].
ELCHUK, S ;
CASSIDY, RM .
ANALYTICAL CHEMISTRY, 1979, 51 (09) :1434-1438
[8]  
Haskin L.A., 1966, PHYS CHEM EARTH, V7, P167, DOI [10.1016/0079-1946(66)90004-8, DOI 10.1016/0079-1946(66)90004-8]
[9]   4-(PYRIDYLAZO)RESORCINOL-BASED CONTINUOUS DETECTION SYSTEM FOR TRACE LEVELS OF METAL-IONS [J].
JEZOREK, JR ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :373-376
[10]   INVERSE PHOTOMETRIC DETECTOR, BASED ON ERIOCHROME BLACK-T, FOR TRACE-METAL DETERMINATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JONES, P ;
HOBBS, PJ ;
EBDON, L .
ANALYST, 1984, 109 (06) :703-707