The mechanical accuracy of several available stereotactic instruments is extremely high as measured in tests with rigid phantoms. The author's experience with stereotactic-guided resection by craniotomy using both ''frameless'' and framed methods simultaneously is that neither the image accuracy nor the mechanical accuracy of the instrument is the limiting factor in the usefulness of the guidance. Rather, it appears that the errors encountered in actual use have to do with tissue position changes which occur during the procedure. The accuracy may be better for extrinsic lesions rigidly attached to the skull, but for intrinsic lesions, tissue position changes occur following the release of cerebrospinal fluid, air entry into the subdural spaces, tumor debulking, or cyst drainage. The potential error appears to be worse with hydrocephalus, intraoperative dehydration, collapse of larger cysts, and debulking of large tumors. Even with very small intrinsic tumors in young, not atrophic patients, the error may be 5 mm. The need for intraoperative update of the guidance image is obvious if greater accuracy is required. The advantages of such ''imaging-interactive'' stereotactic surgery have long been apparent from stereotactic biopsy procedures performed in the CT scanner where errors such as needle deflection or hemorrhage can be appreciated and corrected promptly. With intraoperative scanning it is also possible to monitor the progress of a cyst aspiration and confirm the site of a biopsy to avoid unnecessary sampling in cases where the pathology is inherently equivocal.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 15 条
[1]  
DESALLES AAF, 1987, APPL NEUROPHYSIOL, V50, P23
[2]  
GUTHRIE BL, 1992, CLIN NEUR, V38, P112
[3]   CLINICAL-STUDY ON THE ACCURACY OF THE LAITINEN CT-GUIDANCE SYSTEM IN FUNCTIONAL STEREOTAXIC NEUROSURGERY [J].
HARIZ, MI .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1991, 56 (02) :109-128
[4]   BRAIN-TUMOR RESECTION AIDED WITH MARKERS PLACED USING STEREOTAXIS GUIDED BY MAGNETIC-RESONANCE-IMAGING AND COMPUTED-TOMOGRAPHY [J].
HASSENBUSCH, SJ ;
ANDERSON, JS ;
PILLAY, PK .
NEUROSURGERY, 1991, 28 (06) :801-806
[5]  
Kelly P J, 1990, Adv Tech Stand Neurosurg, V17, P77
[6]   COMPUTER-ASSISTED STEREOTAXIC BIOPSY AND VOLUMETRIC RESECTION OF PEDIATRIC BRAIN-TUMORS [J].
KELLY, PJ .
NEUROLOGIC CLINICS, 1991, 9 (02) :317-336
[7]   ACCURACY OF MR-GUIDED STEREOTAXIC ELECTRODE IMPLANTATION .1. PREIMPLANTATION CORRELATION WITH THE TALAIRACH SYSTEM [J].
LEVESQUE, MF ;
WILSON, CL ;
BEHNKE, EJ ;
ZHANG, JX .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1990, 54-5 :51-55
[8]  
LUNSFORD LD, 1993, NEUROSURGEONS, V12, P170
[9]   THE VALUE OF INTRAOPERATIVE SCANS DURING CT-GUIDED STEREOTAXIC PROCEDURES [J].
PATIL, A ;
KUMAR, P ;
LEIBROCK, L ;
GELBER, B ;
AARABI, B .
NEURORADIOLOGY, 1992, 34 (05) :453-456
[10]  
Roberts D W, 1989, Acta Neurochir Suppl (Wien), V46, P112