FLOW-INJECTION CYTOMETRY - A NEW APPROACH FOR SAMPLE AND SOLUTION HANDLING IN FLOW-CYTOMETRY

被引:18
作者
LINDBERG, W
RUZICKA, J
CHRISTIAN, GD
机构
[1] Department of Chemistry, University of Washington, Seattle, Washington
来源
CYTOMETRY | 1993年 / 14卷 / 02期
关键词
FLOW INJECTION ANALYSIS; ONLINE STAINING; KINETICS; CELL KINETICS; SAMPLE PREPARATION; SOLUTION HANDLING INSTRUMENTATION;
D O I
10.1002/cyto.990140217
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A prototype instrument for sample and solution handling in flow cytometry has been constructed. The system is modular and allows the control of any combination of up to 4 pumps, 2 selection valves, and 2 injection valves. These devices are controlled by a computer using TTL-logic. The flow injection instrument is interfaced to the flow cytometer via a 6-port injection valve, thereby facilitating virtually any flow pattern to be implemented without affecting the fluidics of the cytometer. Salient features of the instrument are accurate control of the volume of injected sample and reagent, reproducible timing, and controlled mixing conditions. Results from model experiments of on-line staining of trout erythrocytes with different concentrations of 4',6-diamidino-2-phenylindole (DAPI) and propidium iodide (PI) are shown. Possible ways to improve the performance and utility of the instrument are also discussed.
引用
收藏
页码:230 / 236
页数:7
相关论文
共 13 条
[1]  
BOX GEP, 1978, STATISTICS EXPT
[2]   TIME WINDOW ANALYSIS AND SORTING [J].
DUNNE, JF .
CYTOMETRY, 1991, 12 (07) :597-601
[3]   LIGAND RECEPTOR INTERNALIZATION - A KINETIC, FLOW CYTOMETRIC ANALYSIS OF THE INTERNALIZATION OF N-FORMYL PEPTIDES BY HUMAN-NEUTROPHILS [J].
FINNEY, DA ;
SKLAR, LA .
CYTOMETRY, 1983, 4 (01) :54-60
[4]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[5]   SAMPLE STATION MODIFICATION PROVIDING ONLINE REAGENT ADDITION AND REDUCED SAMPLE TRANSIT-TIME FOR FLOW CYTOMETERS [J].
KELLEY, KA .
CYTOMETRY, 1989, 10 (06) :796-800
[6]   VERY EARLY DETECTION OF CHANGES ASSOCIATED WITH CELLULAR ACTIVATION USING A MODIFIED FLOW CYTOMETER [J].
KELLEY, KA .
CYTOMETRY, 1991, 12 (05) :464-468
[7]  
Levenspiel O., 1998, CHEM REACTION ENG
[8]  
Nooter K, 1990, Methods Cell Biol, V33, P631
[9]   A CONVENIENT ONLINE DEVICE FOR REAGENT ADDITION, SAMPLE MIXING, AND TEMPERATURE CONTROL OF CELL-SUSPENSIONS IN FLOW-CYTOMETRY [J].
OMANN, GM ;
COPPERSMITH, W ;
FINNEY, DA ;
SKLAR, LA .
CYTOMETRY, 1985, 6 (01) :69-73
[10]   IMPROVED FLOW-CYTOMETRY OF CELLULAR DNA AND RNA BY ONLINE REAGENT ADDITION [J].
PENNINGS, A ;
SPETH, P ;
WESSELS, H ;
HAANEN, C .
CYTOMETRY, 1987, 8 (03) :335-338