PERCENTAGE OF SHORTENING OF ECHOCARDIOGRAPHIC LEFT-VENTRICULAR DIMENSION - ITS USE IN DETERMINING EJECTION FRACTION AND STROKE VOLUME

被引:132
作者
QUINONES, MA
PICKERING, E
ALEXANDER, JK
机构
[1] BAYLOR UNIV,COLL MED,DEPT MED,CANC RES SECT,HOUSTON,TX 77025
[2] BEN TAUB GEN HOSP,HOUSTON,TX
关键词
D O I
10.1378/chest.74.1.59
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The percentage of shortening of the echocardiographic left ventricular dimension (%Δ D) was prospectively evaluated in 42 patients without detectable asynergy during diagnostic cardiac catheterization and was found to correlate well with angiographic ejection fraction (r=0.90). Ejection fraction was calculated as the product of %Δ D x 1.7 or as %Δ(D2), both formulae having similar degrees of accuracy and a better correlation with the angiographic determination than conventional formulae. Ejection fractions (angiographic and echocardiographic) of 51 percent or greater were always associated with a %ΔD of 30 percent or more. In five patients the echocardiographically derived ejection fractions were normal (≥51%), while the angiographic ejection fractions were reduced; four of these patients had valvular regurgitation. End-diastolic volumes were calculated from end-diastolic echocardiographic dimensions utilizing a linear regression equation derived from correlating the end-diastolic echocardiographic dimension with the end-diastolic volume in 27 patients without valvular regurgitation (end-diastolic echocardiographic dimension ranged from 3.7 to 8.2 cm). The value for stroke volume determined as the product of calculated end-diastolic volume times ejection fraction correlated with the angiographically determined stroke volume (r=0.88; standard error of estimate, ±11 ml) better than the value for stroke volume derived from conventional echocardiographic formulae.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 20 条
[1]   COMPARISON OF ULTRASOUND AND CINEANGIOGRAPHIC MEASUREMENTS OF MEAN RATE OF CIRCUMFERENTIAL FIBER SHORTENING IN MAN [J].
COOPER, RH ;
KARLINER, JS ;
PETERSON, KL ;
LEOPOLD, GR ;
OROURKE, RA .
CIRCULATION, 1972, 46 (05) :914-&
[2]   LEFT VENTRICULAR WALL THICKNESS MEASURED BY ULTRASOUND [J].
FEIGENBA.H ;
POPP, RL ;
CHIP, JN ;
HAINE, CL .
ARCHIVES OF INTERNAL MEDICINE, 1968, 121 (05) :391-&
[3]   ULTRASOUND MEASUREMENTS OF LEFT VENTRICLE - CORRELATIVE STUDY WITH ANGIOCARDIOGRAPHY [J].
FEIGENBAUM, H ;
WOLFE, SB ;
TROY, BL ;
DODGE, HT ;
POMBO, JF ;
POPP, RL ;
HAINE, CL .
ARCHIVES OF INTERNAL MEDICINE, 1972, 129 (03) :461-+
[4]   COMPARISON OF EJECTION PHASE INDEXES OF LEFT-VENTRICULAR PERFORMANCE IN INFANTS AND CHILDREN [J].
FISHER, EA ;
DUBROW, IW ;
HASTREITER, AR .
CIRCULATION, 1975, 52 (05) :916-925
[5]   DETERMINATION OF LEFT VENTRICULAR VOLUMES BY ULTRASOUND [J].
FORTUIN, NJ ;
HOOD, WP ;
SHERMAN, ME ;
CRAIGE, E .
CIRCULATION, 1971, 44 (04) :575-&
[6]   EVALUATION OF LEFT-VENTRICULAR SIZE AND FUNCTION BY ECHOCARDIOGRAPHY - RESULTS IN NORMAL CHILDREN [J].
GUTGESELL, HP ;
PAQUET, M ;
DUFF, DF ;
MCNAMARA, DG .
CIRCULATION, 1977, 56 (03) :457-462
[7]   ASSESSMENT OF LEFT-VENTRICULAR FUNCTION IN SEVERE AORTIC REGURGITATION [J].
JOHNSON, AD ;
ALPERT, JS ;
FRANCIS, GS ;
VIEWEG, WVR ;
OCKENE, I ;
HAGAN, AD .
CIRCULATION, 1976, 54 (06) :975-979
[8]   MEASUREMENT OF LEFT VENTRICULAR VOLUMES IN MAN BY SINGLE-PLANE CINEANGIOCARDIOGRAPHY [J].
KASSER, IS ;
KENNEDY, JW .
INVESTIGATIVE RADIOLOGY, 1969, 4 (02) :83-&
[9]  
KENNEDY JW, 1966, CIRCULATION, V34, P272
[10]   LEFT-VENTRICULAR VOLUME MEASUREMENT BY ECHOCARDIOGRAPHY - FACT OR FICTION [J].
LINHART, JW ;
MINTZ, GS ;
SEGAL, BL ;
KAWAI, N ;
KOTLER, MN .
AMERICAN JOURNAL OF CARDIOLOGY, 1975, 36 (01) :114-118