ANALYSIS OF METALLOTHIONEIN ISOFORMS BY CAPILLARY ELECTROPHORESIS - OPTIMIZATION OF PROTEIN SEPARATION CONDITIONS USING MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY

被引:39
作者
BEATTIE, JH [1 ]
RICHARDS, MP [1 ]
机构
[1] USDA ARS, GROWTH BIOL LAB, BELTSVILLE, MD 20705 USA
关键词
D O I
10.1016/0021-9673(94)01167-D
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrophoresis (CE) techniques have been successfully applied to the separation of metallothionein (MT) isoforms and have proved to be rapid, practical and economical. Study of a variety of different electrolytes and capillaries has shown that electrolyte buffer composition and capillary wall surface modifications can have considerable influence on isoform separation and resolution. Ionic surfactants such as sodium dodecyl sulphate (SDS) form micelles at elevated concentrations and the partitioning of molecules between the hydrophobic micelle phase and the aqueous phase and their resulting migration in an electric field is the basis of the technique known as micellar electrokinetic capillary chromatography (MECC). In the present work, we have used sheep and rabbit MT to optimise MECC conditions for analysis of MT isoforms. Capillaries of 57 cm gave much better separations than shorter columns although analysis times were increased to about 12 min. Changing the buffer and SDS concentration or the pH affected the selectivity of isoform separation and up to 5 isoforms in sheep MT and 6 in rabbit MT were completely or partially resolved. Comparing different diameter capillaries we conclude that 25 mu m I.D. columns give better separations than 50 or 75 mu m I.D. columns although sensitivity is reduced by a factor of about 3 and 5, respectively. Using our MECC conditions, columns coated with C-1 or C-18 hydrophobic material were not found to be useful in improving MT separation or resolution although further evaluation of these columns is in progress. Analysis of sheep liver extracts using optimised conditions showed the expression of at least 4 MT isoforms in response to Zn injection and 3 of these forms were evident in extracts from untreated sheep. We therefore conclude that MECC is a suitable method for MT isoform analysis.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 34 条
[1]   SEPARATION OF METALLOTHIONEIN ISOFORMS BY CAPILLARY ZONE ELECTROPHORESIS [J].
BEATTIE, JH ;
RICHARDS, MP ;
SELF, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 632 (1-2) :127-135
[2]   SEPARATION OF METALLOTHIONEIN ISOFORMS BY MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
BEATTIE, JH ;
RICHARDS, MP .
JOURNAL OF CHROMATOGRAPHY A, 1994, 664 (01) :129-134
[3]  
BEATTIE JH, 1994, 42ND P C AM SOC MASS, P667
[4]   METALLOTHIONEIN AND THE TRACE MINERALS [J].
BREMNER, I ;
BEATTIE, JH .
ANNUAL REVIEW OF NUTRITION, 1990, 10 :63-83
[5]  
BRMNER I, 1995, IN PRESS P NUTR SOC
[6]   CAPILLARY ZONE ELECTROPHORESIS AND PACKED CAPILLARY COLUMN LIQUID-CHROMATOGRAPHIC ANALYSIS OF RECOMBINANT HUMAN INTERLEUKIN-4 [J].
BULLOCK, J .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :235-244
[7]   PROTOCOL FOR RESOLVING PROTEIN MIXTURES IN CAPILLARY ZONE ELECTROPHORESIS [J].
GORDON, MJ ;
LEE, KJ ;
ARIAS, AA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1991, 63 (01) :69-72
[8]   PHYSIOLOGICAL-ROLE OF GLUCOCORTICOIDS ON RAT SERUM AND LIVER METALLOTHIONEIN IN BASAL AND STRESS CONDITIONS [J].
HIDALGO, J ;
GIRALT, M ;
GARVEY, JS ;
ARMARIO, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (01) :E71-E78
[9]   PROTEIN AND PEPTIDE MOBILITY IN CAPILLARY ZONE ELECTROPHORESIS - A COMPARISON OF EXISTING MODELS AND FURTHER ANALYSIS [J].
HILSER, VJ ;
WOROSILA, GD ;
RUDNICK, SE .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :329-336
[10]   ZONE ELECTROPHORESIS IN OPEN-TUBULAR GLASS-CAPILLARIES [J].
JORGENSON, JW ;
LUKACS, KD .
ANALYTICAL CHEMISTRY, 1981, 53 (08) :1298-1302