ONLINE COUPLING OF LIQUID-CHROMATOGRAPHY, CAPILLARY GAS-CHROMATOGRAPHY AND MASS-SPECTROMETRY FOR THE DETERMINATION AND IDENTIFICATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN VEGETABLE-OILS

被引:36
作者
VREULS, JJ
DEJONG, GJ
BRINKMAN, UAT
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,DE BOELELAAN 1083,1081 HV AMSTERDAM,NETHERLANDS
[2] DUPHAR BV,DEPT ANALYT DEV,1380 DA WEESP,NETHERLANDS
关键词
COUPLED LC-GC-MS; POLYCYCLIC AROMATIC HYDROCARBONS; VEGETABLE OIL SAMPLES;
D O I
10.1007/BF02274556
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An on-line combination of liquid chromatography, gas chromatography and mass spectrometry has been realized by coupling a quadrupole mass spectrometer to an LC-GC apparatus. Liquid chromatography was used for sample pretreatment of oil samples of different origin. The appropriate LC fraction, containing polycyclic aromatic hydrocarbons, was transferred to the gas chromatograph using a loop-type interface. After solvent evaporation through the solvent vapour exit and subsequent GC separation, the compounds were introduced into the mass spectrometer for detection and identification. The GC column was connected to a short piece of deactivated fused silica that protruded into the ion source. The total analytical set-up allowed the direct analysis of oil samples after dilution in n-pentane without any sample clean-up. Detection limits are about 40 pg in the full scan mode and about 1 pg with selective ion monitoring, i.e. 20 ppb and 0.5 ppb respectively.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 7 条
[1]  
DAVIES IL, 1989, HRC-J HIGH RES CHROM, V12, P193
[2]   LOOP-TYPE INTERFACE FOR CONCURRENT SOLVENT EVAPORATION IN COUPLED HPLC-GC - ANALYSIS OF RASPBERRY KETONE IN A RASPBERRY SAUCE AS AN EXAMPLE [J].
GROB, K ;
STOLL, JM .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (09) :518-523
[3]  
GROB K, 1989, HRC-J HIGH RES CHROM, V12, P375
[4]   MINIMUM COLUMN TEMPERATURE REQUIRED FOR CONCURRENT SOLVENT EVAPORATION IN COUPLED HPLC-GC [J].
GROB, K ;
LAUBLI, T .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (08) :435-440
[5]   COUPLING OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
FROHLICH, D ;
SCHILLING, B ;
NEUKOM, HP ;
NAGELI, P .
JOURNAL OF CHROMATOGRAPHY, 1984, 295 (01) :55-61
[6]   COUPLING HPLC TO GC - WHY - HOW - WITH WHAT INSTRUMENTATION [J].
MUNARI, F ;
GROB, K .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (02) :61-66
[7]  
Speer K., 1990, Journal of High Resolution Chromatography and Chromatography Communications, V13, P104, DOI 10.1002/jhrc.1240130206