摘要
Totally implanted central-venous access devices are frequently used for the administration of chemotherapy or parenteral nutrition. Catheter fracture is a rare complication of these devices, with an estimated rate of 0.1%. We have lately seen three cases of catheter fracture with embolization of a catheter fragment to the heart and pulmonary vessels, These cases are described in this article, Catheter fracture is caused by intermittent compression of the catheter between the clavicula and the first rib, which can occur when the catheter has been inserted too far medially. When, on an X-ray of the chest, the catheter is shown to be compressed at the point where the clavicula crosses the first rib, or when infusion through the device suddenly becomes difficult, the chance of catheter fracture is high and the device should be removed.
引用
收藏
页码:432 / 434
页数:3
相关论文
共 12 条
[1]  
BARRIOS CH, 1994, ONCOLOGY, V49, P474
[2]  
BROTHERS TE, 1988, SURG GYNECOL OBSTET, V166, P295
[3]   CATHETER FRACTURE AND EMBOLIZATION IN A TOTALLY IMPLANTED VENOUS ACCESS CATHETER [J].
FRANEY, T ;
DEMARCO, LC ;
GEISS, AC ;
WARD, RJ .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1988, 12 (05) :528-530
[4]   EARLY AND LATE COMPLICATIONS OF TOTALLY IMPLANTABLE VENOUS ACCESS DEVICES [J].
GRANNAN, KJ ;
TAYLOR, PH .
JOURNAL OF SURGICAL ONCOLOGY, 1990, 44 (01) :52-54
[5]  
HEM KG, 1991, NETH J MED, V38, P262
[6]   PINCH-OFF SYNDROME - A COMPLICATION OF IMPLANTABLE SUBCLAVIAN VENOUS ACCESS DEVICES [J].
HINKE, DH ;
ZANDTSTASTNY, DA ;
GOODMAN, LR ;
QUEBBEMAN, EJ ;
KRZYWDA, EA ;
ANDRIS, DA .
RADIOLOGY, 1990, 177 (02) :353-356
[7]   SPONTANEOUS PARTIAL FRACTURE OF THE CATHETER OF A TOTALLY IMPLANTABLE SUBCUTANEOUS INFUSION PORT [J].
INOUE, Y ;
NEZU, R ;
NAKAI, S ;
TAKAGI, Y ;
OKADA, A .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1992, 16 (01) :75-77
[9]   COMPLICATIONS AND MANAGEMENT OF IMPLANTED VENOUS ACCESS CATHETERS [J].
LOKICH, JJ ;
BOTHE, A ;
BENOTTI, P ;
MOORE, C .
JOURNAL OF CLINICAL ONCOLOGY, 1985, 3 (05) :710-717
[10]   SPONTANEOUS FRACTURE OF THE CATHETER OF A TOTALLY IMPLANTABLE VENOUS ACCESS PORT - CASE-REPORT OF A RARE COMPLICATION [J].
NOYEN, J ;
HOORNTJE, J ;
DELANGEN, Z ;
LEEMSLAG, JW ;
SLEIJFER, D .
JOURNAL OF CLINICAL ONCOLOGY, 1987, 5 (08) :1295-1299