MICRODOSIMETRIC CONCEPTS IN RADIOIMMUNOTHERAPY

被引:64
作者
HUMM, JL
ROESKE, JC
FISHER, DR
CHEN, GTY
机构
[1] UNIV CHICAGO, MED CTR, CHICAGO, IL 60637 USA
[2] PACIFIC NW LAB, RICHLAND, WA 99352 USA
关键词
MICRODOSIMETRY; RADIOLABELED ANTIBODIES; ENERGY DEPOSITION; ALPHA-EMITTERS; BETA-EMITTERS;
D O I
10.1118/1.597049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In microdosimetry particular emphasis is placed on the stochastic fluctuation of dose in small target volumes such as individual cell nuclei or chromatin fiber, and their relevance to radiobiologic toxicity. Thus microdosimetry is intimately associated with models of radiation action. There are three principal areas where microdosimetry has been applied: (1) radiation protection, (2) high LET radiotherapy, e.g., neutron therapy, and (3) incorporated radionuclides, and in this latter category the importance of microdosimetry to the radiobiology of radiolabeled antibodies is becoming increasingly recognized. The objective of microsdosimetry is the complete characterization of energy deposition within all target volumes throughout the tissue of interest. The importance and relevance of this pursuit will depend upon the properties of the radionuclide emissions and the spatial distribution of the radionuclide relative to the target volumes. If the distribution of internal emitters within both malignant and normal tissue is uniform, the application of microdosimetry to radioimmunotherapy (RIT) is limited to alpha-emitters and Auger emitters. Under such circumstances the traditional MIRD formalism for the evaluation of tumor and tissue doses from the commonly used beta-emitters is entirely adequate. This, however, is rarely the case. When the distribution of radiolabeled antibody is nonuniform, techniques of dose averaging over volumes greater in size than the individual target volumes can become inadequate predictors of the biological effect. The concepts, methods, and realm of applicability of microdosimetry within the field of radioimmunotherapy are emphasized in this paper.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 34 条
[1]  
Auger P., 1925, CR HEBD ACAD SCI, V180, P65
[2]  
BOND VP, 1985, RADIAT RES, V104, pS52
[3]   A RELATIONSHIP BETWEEN MICRODOSIMETRIC SPECTRA AND CELL-SURVIVAL FOR HIGH-LET IRRADIATION [J].
CHARLTON, DE ;
SEPHTON, R .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1991, 59 (02) :447-457
[4]  
FISHER DR, 1986, 4TH INT S RAD DOS S, P446
[5]  
GAEDICKE FS, 1992, RADIOTHER ONCOL, V23, P150
[6]   A WALL-LESS DETECTOR FOR MEASURING ENERGY DEPOSITION SPECTRA [J].
GLASS, WA ;
BRABY, LA .
RADIATION RESEARCH, 1969, 39 (02) :230-&
[7]  
GOODHEAD DT, 1987, DOSIMETRY IONIZING R, V2, P1
[8]  
GRIFFITH MH, 1988, J NUCL MED, V29, P1795
[9]  
HOFER KG, 1980, B CANCER, V67, P343
[10]   MACROSCOPIC DOSIMETRY FOR RADIOIMMUNOTHERAPY - NONUNIFORM ACTIVITY DISTRIBUTIONS IN SOLID TUMORS [J].
HOWELL, RW ;
RAO, DV ;
SASTRY, KSR .
MEDICAL PHYSICS, 1989, 16 (01) :66-74