TRANSTHORACIC AND TRANSESOPHAGEAL ECHOCARDIOGRAPHIC SIZING OF THE AORTIC ANNULUS TO DETERMINE PROSTHESIS SIZE

被引:12
作者
HARPAZ, D
SHAH, P
BEZANTE, G
HEO, MS
STEWART, S
HICKS, GL
HALL, WJ
MELTZER, RS
机构
[1] UNIV ROCHESTER,CARDIOL UNIT,ROCHESTER,NY 14627
[2] UNIV ROCHESTER,MED CTR,CTR BIOMED ULTRASOUND,DEPT ANESTHESIOL,ROCHESTER,NY 14642
[3] UNIV ROCHESTER,MED CTR,DEPT BIOSTAT,ROCHESTER,NY 14642
[4] UNIV ROCHESTER,MED CTR,DEPT CARDIOTHORAC SURG,ROCHESTER,NY 14642
关键词
D O I
10.1016/0002-9149(93)90189-J
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the accuracy of 2-dimensional echocardiography versus transesophageal echocardiography (TEE) in predicting aortic annulus diameter, and to determine which part of the cardiac cycle should be used for measuring the size of the aortic valve prosthesis in patients undergoing aortic valve replacement, the aortic annulus was measured retrospectively in a blinded fashion in a group of 94 patients who had undergone aortic valve replacement: 66 had preoperative transthoracic echocardiography (TTE), 69 had intraoperative TEE, and 41 had both. Accuracy of measurements was calculated by the mean biases (differences between annular size by echo and actual valve size chosen by intraoperative mechanical sizing of the aortic annulus). TTE was compared with TEE and end-diastolic (ED) measurements with end-systolic (ES) measurements. The mean biases +/- SD were -1.7 +/- 3.4 mm by TEE-ES versus -0.9 +/- 3.5 mm by TEE-ES measurements (p = NS), and +0.03 +/- 3 mm by TTE-ED versus +0.5 +/- 2.8 mm by TEE-ED (p = NS). Examination of the magnitudes of the biases gave the same result. ED measurements were found to have a smaller amount of bias than ES measurements, both by TTE and by TEE: -1.7 +/- 3.4 mm by TTE-ES versus +0.03 +/- 3 mm by TTE-ED (p = 0.0001) and -0.9 +/- 3.5 mm by TEE-ES versus +0.5 +/- 2.8 mm by TEE-ED (p = 0.0001). Examination of the magnitudes of the biases also gave the same result. Thus, TTE (as well as TEE) can predict valve size in patients undergoing aortic valve replacement. ED annular sizing better predicts valve size than ES sizing. These results can be used clinically in the assessment of patients undergoing aortic valve replacement.
引用
收藏
页码:1411 / 1417
页数:7
相关论文
共 13 条
[1]   PREOPERATIVE TWO-DIMENSIONAL ECHOCARDIOGRAPHIC PREDICTION OF PROSTHETIC AORTIC AND MITRAL-VALVE SIZE IN CHILDREN [J].
CALDWELL, RL ;
GIROD, DA ;
HURWITZ, RA ;
MAHONY, L ;
KING, H ;
BROWN, J .
AMERICAN HEART JOURNAL, 1987, 113 (04) :873-878
[2]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC PREOPERATIVE PREDICTION OF PROSTHETIC AORTIC-VALVE SIZE [J].
COHEN, JL ;
AUSTIN, SM ;
KIM, CS ;
CHRISTAKOS, ME ;
HUSSAIN, SM .
AMERICAN HEART JOURNAL, 1984, 107 (01) :108-112
[3]  
COX DR, 1974, THEORETICAL STATISTI, P279
[4]  
Emerson JD, 1983, UNDERSTANDING ROBUST, P58
[5]  
FRANCIS GS, 1975, BRIT HEART J, V37, P376
[6]  
JUTILA C, 1991, Journal of the American College of Cardiology, V17, p315A
[7]  
KIRKLIN JW, 1988, CARDIAC SURGERY, P373
[8]  
MACKAY A, 1985, BRIT HEART J, V53, P507
[9]  
MOSCUCCI M, 1991, CIRCULATION, V84, P76
[10]  
Mosteller F., 1977, DATA ANAL REGRESSION, P133