MR IMAGING OF LIVER METASTASES AT 1.5 T - SIMILAR CONTRAST DISCRIMINATION WITH T1-AND T2-WEIGHTED PULSE SEQUENCES

被引:21
作者
SAINI, S
LI, W
WALLNER, B
HAHN, PF
EDELMAN, RR
机构
[1] HARVARD UNIV,MASSACHUSETTS GEN HOSP,DEPT RADIOL,BOSTON,MA 02114
[2] BETH ISRAEL HOSP,BOSTON,MA 02215
[3] UNIV ULM,W-7900 ULM,GERMANY
[4] CAPITAL INST MED,BEIJING FRIENDSHIP HOSP,BEIJING,PEOPLES R CHINA
关键词
LIVER NEOPLASMS; MR STUDIES; SECONDARY; MAGNETIC RESONANCE (MR); PULSE SEQUENCES;
D O I
10.1148/radiology.181.2.1924787
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors evaluated soft-tissue contrast on spin-echo (SE) proton density-weighted, SE T2-weighted, SE short-echo-time (TE) T1-weighted, and gradient-echo (GRE) images of 34 patients with known hepatic tumors who underwent high-field-strength (1.5-T) magnetic resonance imaging. For solid liver tumors, the difference in the mean lesion-liver contrast-to-noise ratios (C/Ns) with T1- (GRE and SE) and T2-weighted pulse sequences was not statistically significant (P > .05). For nonsolid liver tumors, the T2-weighted images provided significantly greater (P < .05) mean lesion-liver C/N than T1-weighted GRE images. Mean liver signal-to-noise ratio was significantly greater on T1-weighted GRE (P < .0001) and T1-weighted SE (P < .05) images than on T2- and proton density-weighted images. Qualitative analysis of T1-weighted (SE and GRE) images and proton density- plus T2-weighted images showed that lesion conspicuity was similar in 25 of 32 patients (78%). The results suggest that liver tumor imaging at high field strength can be performed with short-TE T1-weighted (SE or GRE) or conventional T2-weighted pulse sequences.
引用
收藏
页码:449 / 453
页数:5
相关论文
共 17 条
  • [1] RAPID MR IMAGING WITH SUSPENDED RESPIRATION - CLINICAL-APPLICATION IN THE LIVER
    EDELMAN, RR
    HAHN, PF
    BUXTON, R
    WITTENBERG, J
    FERRUCCI, JT
    SAINI, S
    BRADY, TJ
    [J]. RADIOLOGY, 1986, 161 (01) : 125 - 131
  • [2] HEPATIC-TUMORS - QUANTITATIVE TISSUE CHARACTERIZATION WITH MR IMAGING
    EGGLIN, TK
    RUMMENY, E
    STARK, DD
    WITTENBERG, J
    SAINI, S
    FERRUCCI, JT
    [J]. RADIOLOGY, 1990, 176 (01) : 107 - 110
  • [3] LIVER-TUMOR IMAGING - CURRENT CONCEPTS
    FERRUCCI, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (03) : 473 - 484
  • [4] FERRUCCI JT, 1988, RADIOLOGY, V168, P319
  • [5] CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T
    FOLEY, WD
    KNEELAND, JB
    CATES, JD
    KELLMAN, GM
    LAWSON, TL
    MIDDLETON, WD
    HENDRICK, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) : 1155 - 1160
  • [6] HENDRICK R E, 1984, Magnetic Resonance Imaging, V2, P193, DOI 10.1016/0730-725X(84)90005-5
  • [7] OPTIMAL PULSE SEQUENCE FOR IMAGING HEPATIC METASTASES
    HENKELMAN, RM
    HARDY, P
    POON, PY
    BRONSKILL, MJ
    [J]. RADIOLOGY, 1986, 161 (03) : 727 - 734
  • [8] HEPATIC HEMANGIOMAS VS METASTASES - MR DIFFERENTIATION AT 1.5-T
    LOMBARDO, DM
    BAKER, ME
    SPRITZER, CE
    BLINDER, R
    MEYERS, W
    HERFKENS, RJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (01) : 55 - 59
  • [9] LIVER AND PANCREAS - IMPROVED SPIN-ECHO T1 CONTRAST BY SHORTER ECHO TIME AND FAT SUPPRESSION AT 1.5-T
    MITCHELL, DG
    VINITSKI, S
    SAPONARO, S
    TASCIYAN, T
    BURK, DL
    RIFKIN, MD
    [J]. RADIOLOGY, 1991, 178 (01) : 67 - 71
  • [10] NELSON T R, 1984, Magnetic Resonance Imaging, V2, P285, DOI 10.1016/0730-725X(84)90194-2