CAN A CLINICIAN PREDICT THE TECHNICAL EQUIPMENT A PATIENT WILL NEED DURING INTENSIVE-CARE UNIT TREATMENT - AN APPROACH TO STANDARDIZE AND REDESIGN THE INTENSIVE-CARE UNIT WORKSTATION

被引:5
作者
HAHNEL, J
FRIESDORF, W
SCHWILK, B
MARX, T
BLESSING, S
机构
[1] From the Department of Anaesthesia, University of Ulm, Ulm
来源
JOURNAL OF CLINICAL MONITORING | 1992年 / 8卷 / 01期
关键词
EQUIPMENT; INTENSIVE CARE UNITS;
D O I
10.1007/BF01618079
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The technical equipment of today's intensive care unit (ICU) workstation has been characterized by a gradual, incremental accumulation of individual devices, whose presence is dictated by patient needs. These devices usually present differently designed controls, operate under different alarm philosophies, and cannot communicate with each other. By contrast, ICU workstations could be equipped permanently and in a standardized manner with electronically linked modules if the attending physicians could reliably predict, at the time of admission, the patient's equipment needs. Over a period of 3 1/2 months, the doctors working in our 20-bed surgical ICU made 1,000 predictions concerning outcome, equipment need, duration of artificial ventilation, and duration of hospitalization for 300 recently admitted patients. The interviews were made within the first 24 hours after admission. The doctors being interviewed were usually (i.e., in over 90% of cases) unfamiliar with the patient. Information concerning the patient's general state of health, special pre-ICU events, and complications was offered to the interviewed clinician because this information represents standard admission data. It was found that the equipment need (represented by two different setups, "high tech" and "low tech") could be predicted most reliably (96.4% correct predictions) compared with a prediction on outcome of ICU treatment (94.5%), on duration of artificial ventilation (75.4%), and on duration of stay (43.4%). There was no significant (p > 0.05) difference in the reliability of predictions between residents and consultants. Factors influencing the postoperative equipment need varied with surgical specialty. The general state of health, as indicated by the ASA classification (p < 0.001), and the specific intervention (all multiple-valve replacements needed the high-level equipment standard) appeared to be most important in cardiac surgery, while a state of septicemia was important in general surgery (p < 0.001). Our findings suggest that ICU workstations may be standardized into at least two types.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 12 条
[1]  
Knaus W.A., Zimmerman J.E., Wagner D.P., Draper E.A., Lawrence D.E., APACHE—acute physiology and chronic health evaluation: a physiologically based classification system, Crit Care Med, 9, pp. 591-597, (1981)
[2]  
Knaus W.A., Draper E.A., Wagner D.P., Zimmerman J.E., APACHE II: a severity of disease classification system, Crit Care Med, 13, pp. 818-829, (1985)
[3]  
Lehmkuhl P., Lips U., Pichlmayr I., Der Hannover Intensiv Score (HIS) als neues Klassifikationssystem zu Verlaufskontrollen und Prognosestellung bei Intersivpatienten, Med Klin, 81, pp. 235-240, (1986)
[4]  
Riffel B., Stohr M., Graser W., Trost E., Baumgartner H., Frühzeitige Prognose beim schweren Schädel-Hirn-Trauma mittels Glasgow-Koma-Score und evozierter Potentiale, Anaesthesist, 38, pp. 51-58, (1989)
[5]  
Obertacke U., Kalotai J., Coenen T., Joka T., Schmid-Neuerburg K.P., Ein linearer ARDS-Schweregradscore, Intensivmed, 25, pp. 264-267, (1988)
[6]  
Seefelder C., Matzek N., Rossi R., Polytrauma-Bewertungsskalen
[7]  
Teil I: Aufgaben, Anforderungen, Einteilungen, Noffallmedizin, 14, pp. 227-236, (1988)
[8]  
Seefelder C., Matzek N., Rossi R., Polytrauma-Bewertungsskalen
[9]  
Teil II: Trauma Score und Injury Severity Score, Noffallmedizin, 14, pp. 317-329, (1988)
[10]  
Hopefl A.W., Taaffe C.L., Herrmann V.M., Failure of APACHE II alone as a predictor of mortality in patients receiving total parenteral nutrition, Crit Care Med, 17, pp. 414-417, (1989)