DETERMINATION OF COPPER AND ALUMINUM IN STEEL BY MEANS OF HOLLOW-CATHODE AND GLOW-DISCHARGE LIGHT-SOURCES - COMPARATIVE-STUDY

被引:14
作者
CAROLI, S
ALIMONTI, A
DELLEFEMMINE, P
机构
[1] Laboratorio di Tossicologia, Istituto Superiore di Sanita, 00161, Rome, Viale Regina Elena
关键词
Aluminium; Copper; Emission Spectroscopy; Glow Discharge; Hollow Cathode; Steel;
D O I
10.1080/00387017908069211
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The applicability of hollow cathode and glow discharge light sources to the determination of minor constituents in steel1 was tested in the case of copper (0,033 - 0.34 [Wt]%) and aluminium (0,015 - 0.16 %). The linearity of the calibration graphs, reflected by the Bravais-Pearson coefficient, was found to be slightly improved in all the cases investigated when operating with hollow cathode. Furthermore, results showed that blackening values of the analytical lines can be plotted directly without resorting to reference lines. © 1979 Taylor & Francis Group, LLC. All Rights Reserved.
引用
收藏
页码:871 / 886
页数:16
相关论文
共 11 条
[1]  
ANZANI R, 1968, 14 P SEM SPECTR AIM, P1
[3]   COMPARATIVE INVESTIGATIONS OF HOLLOW-CATHODE AND GLOW-DISCHARGE LIGHT-SOURCES - FURTHER CONSIDERATIONS [J].
CAROLI, S ;
DELLEFEMMINE, P .
SPECTROSCOPY LETTERS, 1978, 11 (05) :299-321
[4]  
CAROLI S, 1976, KEM KOZL, V45, P137
[5]  
CAROLI S, 1977, SPECTR LETT, V8, P655
[6]  
CAROLI S, 1979, 21 CSI 8TH ICAS CAMB
[7]  
DIEUDONNE H, 1970, DS775 PROJ
[9]   GLOW DISCHARGE LAMP FOR ROUTINE SPECTROANALYTIC MEASUREMENTS [J].
GRIMM, W .
NATURWISSENSCHAFTEN, 1967, 54 (22) :586-&
[10]  
MILAZZO G, 1972, CHEM ANAL-WARSAW, V17, P891