REVISION OF FAILED KNEE REPLACEMENTS USING FIXED-AXIS HINGES

被引:70
作者
INGLIS, AE [1 ]
WALKER, PS [1 ]
机构
[1] ROYAL NATL ORTHOPAED HOSP,INST ORTHOPAED,DEPT BIOMED ENGN,STANMORE HA7 4LP,MIDDX,ENGLAND
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1991年 / 73卷 / 05期
关键词
D O I
10.1302/0301-620X.73B5.1894661
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Forty failed hinged arthroplasties of the knee were revised by the insertion of another hinged implant. In 14 cases the prosthesis used at the revision operation was similar to the primary implant; in 26, a hinge with an elongated femoral stem was used, usually replacing part of the femoral shaft. In seven of these knees an elongated tibial stem was also required, though the tibial shaft was replaced in only two of them. There were many complications. Fracture of the femur at the tip of the femoral stem was the most frequent. Sixteen first revisions failed and were revised a second time; 12 required replacement of the distal femoral shaft and three required replacement of the proximal tibia. The incidence of complications in knees requiring a second revision was even higher. Four required a third revision after an average interval of three years. Failure of a hinged prosthesis results in bone loss mainly in the femur. Revision of a failed hinged prosthesis with another of the same design is unlikely to be successful and may cause fracture of the femur.
引用
收藏
页码:757 / 761
页数:5
相关论文
共 12 条
[1]
STEMMED REVISION ARTHROPLASTY FOR ASEPTIC LOOSENING OF TOTAL KNEE REPLACEMENT [J].
BERTIN, KC ;
FREEMAN, MAR ;
SAMUELSON, KM ;
RATCLIFFE, SS ;
TODD, RC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02) :242-248
[2]
DONALDSON WF, 1988, CLIN ORTHOP RELAT R, V226, P21
[3]
THE LONG-TERM RESULTS OF STANMORE TOTAL KNEE REPLACEMENTS [J].
GRIMER, RJ ;
KARPINSKI, MRK ;
EDWARDS, AN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (01) :55-62
[4]
HINGED KNEE PROSTHESES - STILL ADVISABLE - 15 YEARS EXPERIENCE WITH THE BLAUTH KNEE [J].
HASSENPFLUG, J ;
HARTEN, K ;
HAHNE, HJ ;
HOBECK, K ;
HOLLAND, C ;
MARONNA, U .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1988, 126 (04) :398-407
[5]
INGLIS AE, 1991, IN PRESS CLIN ORTHOP
[6]
KARPINSKI MRK, 1987, CLIN ORTHOPAEDICS, V220, P185
[7]
ASSESSMENT OF THE SURVIVAL AND THE CLINICAL-RESULTS OF STANMORE TOTAL KNEE REPLACEMENTS [J].
LETTIN, AWF ;
KAVANAGH, TG ;
CRAIG, D ;
SCALES, JT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03) :355-361
[8]
THE LONG-TERM RESULTS OF STANMORE TOTAL KNEE REPLACEMENTS [J].
LETTIN, AWF ;
KAVANAGH, TG ;
SCALES, JT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03) :349-354
[9]
KINEMATIC ROTATING-HINGE TOTAL KNEE ARTHROPLASTY [J].
RAND, JA ;
CHAO, EYS ;
STAUFFER, RN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (04) :489-497
[10]
ROOSER B, 1987, CLIN ORTHOPAEDICS, V219, P169