CORRELATION BETWEEN PLASMA AND URINE GLUCOSE IN DIABETES

被引:49
作者
MORRIS, LR
MCGEE, JA
KITABCHI, AE
机构
[1] UNIV TENNESSEE, CTR HLTH SCI, DEPT MED, DIV ENDOCRINOL & METAB, MEMPHIS, TN 38163 USA
[2] UNIV TENNESSEE, CTR HLTH SCI, CLIN RES CTR, MEMPHIS, TN 38163 USA
[3] CITY MEMPHIS HOSP, MEMPHIS, TN USA
关键词
D O I
10.7326/0003-4819-94-4-469
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine whether semiquantitative glucose measurements of spot urine specimens accurately reflect prevailing plasma glucose levels, reported levels from 400 2nd-voided urines were compared to simultaneous plasma determinations from 246 human adult diabetics. Quantitative urine levels and plasma glucose levels correlated. When semiquantitative urinary determinations were compared to plasma glucose stratified into 0-149, 150-199, and greater than 200 mg/dl, 75% of the urine samples associated with plasma levels from 150-199 mg/dl were negative by Diastix, and 16.5% of samples negative by Diastix were in the 200 + mg/dl plasma range. Only 9% of samples from 0-149 mg/dl showed any positive Diastix readings. Because of the low sensitivity of semiquantitative methods, spot urine glucose determinations except for detection of marked hyperglycemia, are inadequate as the sole means of clinical assessment for management of diabetic patients. Home glucose monitoring may be a better alternative for follow-up of these patients.
引用
收藏
页码:469 / 471
页数:3
相关论文
共 34 条
[1]   COMPARISON OF BENEDICTS SOLUTION, CLINITEST, TES-TAPE AND CLINISTIX [J].
ACKERMAN, RF ;
WILLIAMS, EF ;
PACKER, H ;
HAWKES, JH ;
AHLER, J .
DIABETES, 1958, 7 (05) :398-402
[2]   URINE SUGAR DETERMINATION BY 2-DROP CLINITEST METHOD [J].
BELMONTE, MM ;
SARKOZY, E ;
HARPUR, ER .
DIABETES, 1967, 16 (08) :557-&
[3]  
Benedict SR, 1909, J BIOL CHEM, V5, P485
[4]   SYMPOSIUM ON HOME BLOOD-GLUCOSE MONITORING - CHAIRMANS INTRODUCTION [J].
BLEICHER, SJ .
DIABETES CARE, 1980, 3 (01) :57-57
[5]   RENAL GLUCOSE THRESHOLD VARIATIONS WITH AGE [J].
BUTTERFIELD, WJ ;
KEEN, H ;
WHICHELOW, MJ .
BMJ-BRITISH MEDICAL JOURNAL, 1967, 4 (5578) :505-+
[6]   CONTROL AND DIABETES [J].
CAHILL, GF ;
ETZWILER, DD ;
FREINKEL, N .
NEW ENGLAND JOURNAL OF MEDICINE, 1976, 294 (18) :1004-1005
[7]   SEMIQUANTITATIVE SPECIFIC TEST PAPER FOR GLUCOSE IN URINE [J].
COMER, JP .
ANALYTICAL CHEMISTRY, 1956, 28 (11) :1748-1750
[8]   DIASTIX AND KETODIASTIX - NEW SEMIQUANTITATIVE TEST FOR GLUCOSE IN URINE [J].
COURT, JM ;
DAVIES, HE ;
FERGUSON, R .
MEDICAL JOURNAL OF AUSTRALIA, 1972, 1 (11) :525-&
[9]   ACCURACY OF URINE TESTING FOR SUGAR AND ACETONE BY HOSPITAL WARD PERSONNEL [J].
DOBSON, HL ;
SHAFFER, R ;
BURNS, R .
DIABETES, 1968, 17 (05) :281-&
[10]  
DYERBERG J, 1976, CLIN CHEM, V22, P205