DECONTAMINATION OF INSTRUMENTS AND CONTROL OF CROSS INFECTION IN GENERAL-PRACTICE

被引:18
作者
MORGAN, DR [1 ]
LAMONT, TJ [1 ]
DAWSON, JD [1 ]
BOOTH, C [1 ]
机构
[1] BRITISH MED ASSOC,BOARD SCI & EDUC,LONDON WC1H 9JP,ENGLAND
关键词
D O I
10.1136/bmj.300.6736.1379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the effectiveness of decontamination procedures in general practice. Anonymous postal questionnaire survey of 600 general practitioners randomly selected from the national register. 382 General practitioners, a response rate of 65%. 186 General practitioners had autoclaves but 125 used hot water disinfectors or chemical disinfectants to reprocess instruments. 22% (474/2132) Of high risk instruments were inadequately decontaminated. Decontamination was performed by the practice nurse or receptionist in 306 practices. Knowledge of treatment of spillages of blood fluids was uncertain, and only 114 general practitioners used effective methods for dealing with spillages. A comprehensive central code of practice for control of infection is needed for primary health care staff.
引用
收藏
页码:1379 / 1380
页数:2
相关论文
共 6 条
[1]   SURVEY OF EQUIPMENT IN GENERAL-PRACTICE [J].
BRADLEY, N ;
WATKINS, S .
BRITISH MEDICAL JOURNAL, 1989, 299 (6696) :435-436
[2]  
FARROW SC, 1988, J ROY COLL GEN PRACT, V38, P447
[3]   CONTROL OF INFECTION IN GENERAL-PRACTICE - A SURVEY AND RECOMMENDATIONS [J].
HOFFMAN, PN ;
COOKE, EM ;
LARKIN, DP ;
SOUTHGATE, LJ ;
MAYONWHITE, RT ;
PETHER, JVS ;
WRIGHT, AE ;
KEENLYSIDE, D .
BRITISH MEDICAL JOURNAL, 1988, 297 (6640) :34-36
[4]  
ROGERS J, 1989, NURS TIMES, V85, P5
[5]  
1989, CODE PRACTICE STERIL
[6]  
1987, SURVEY METHODS NEWSL