THE TOTAL NUMBER OF NEURONS IN THE HUMAN NEOCORTEX UNBIASEDLY ESTIMATED USING OPTICAL DISECTORS

被引:258
作者
BRAENDGAARD, H
EVANS, SM
HOWARD, CV
GUNDERSEN, HJG
机构
[1] UNIV LIVERPOOL,PSYCHIAT CLIN & POLYCLIN,LIVERPOOL L69 3BX,ENGLAND
[2] UNIV LIVERPOOL,DEPT HUMAN ANAT & CELL BIOL,QUANTIT 3D MICROSCOPY GRP,LIVERPOOL L69 3BX,ENGLAND
[3] AARHUS UNIV,DEPT NEUROL,DK-8000 AARHUS C,DENMARK
[4] AARHUS UNIV,INST EXPTL CLIN RES,STEREOL RES LAB,DK-8000 AARHUS C,DENMARK
[5] AARHUS UNIV,INST PATHOL,DK-8000 AARHUS C,DENMARK
[6] AARHUS UNIV,INTERNAL MED CLIN 2,DK-8000 AARHUS C,DENMARK
来源
JOURNAL OF MICROSCOPY-OXFORD | 1990年 / 157卷
关键词
Brain; Cavalieri estimate; counting; disector; human; morphometry; neocortex; neurons; number; stereology;
D O I
10.1111/j.1365-2818.1990.tb02967.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
An efficient method is presented for obtaining, in under 4h, an unbiased estimate of the total number of neurons in the human neocortex, with a coefficient of error on the estimate of ∼ 5%. The novel sampling scheme used in this study is unbiased and was designed so that only a small amount of neocortical grey matter had to be removed. Hence, the majority of the cerebral grey matter and all the internal grey matter was left intact for further resampling and analysis. Each cerebral hemisphere was subdivided into the four major neocortical regions, sliced coronally at 7‐mm intervals and the volume of the neocortex determined using Cavalieri's principle. Uniform sampling of neocortex was performed in the hemisphere followed by regional subsampling with a varying sampling fraction being taken from each region. Neuronal density estimates were made in thick plastic sections using optical disectors. Shrinkage estimates were made in parallel with the number estimates and found to be negligible. The total number of neocortical neurons in the right hemisphere of five normal 80‐year‐old men was found to be 13·7 × 109 with an inter‐individual coefficient of variation of 12%. 1990 Blackwell Science Ltd
引用
收藏
页码:285 / 304
页数:20
相关论文
共 20 条
[1]  
BADDELY AJ, 1986, J MICROSC, V131, P259
[2]   UNBIASED ESTIMATION OF PARTICLE NUMBER USING SECTIONS - AN HISTORICAL-PERSPECTIVE WITH SPECIAL REFERENCE TO THE STEREOLOGY OF GLOMERULI [J].
BENDTSEN, TF ;
NYENGAARD, JR .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 :93-102
[3]  
Cochran W. G., 2007, SAMPLING TECHNIQUES
[4]  
COOPER JD, 1988, J ANAT, V157, P13
[5]  
GUNDERSEN, 1981, STEREOLOGI ELLER HVO
[6]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[7]   THE NEW STEREOLOGICAL TOOLS - DISECTOR, FRACTIONATOR, NUCLEATOR AND POINT SAMPLED INTERCEPTS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS [J].
GUNDERSEN, HJG ;
BAGGER, P ;
BENDTSEN, TF ;
EVANS, SM ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (10) :857-881
[8]   THE NUCLEATOR [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY-OXFORD, 1988, 151 :3-21
[9]   STEREOLOGY OF ARBITRARY PARTICLES - A REVIEW OF UNBIASED NUMBER AND SIZE ESTIMATORS AND THE PRESENTATION OF SOME NEW ONES, IN MEMORY OF THOMPSON,WILLIAM,R. [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1986, 143 :3-45
[10]   THE EFFECTS OF EMBEDDING IN WATER-SOLUBLE PLASTICS ON THE FINAL DIMENSIONS OF LIVER SECTIONS [J].
HANSTEDE, JG ;
GERRITS, PO .