ESTIMATION OF TOTAL-BODY AND EXTRACELLULAR WATER USING SINGLE-FREQUENCY AND MULTIPLE-FREQUENCY BIOIMPEDANCE

被引:48
作者
PATEL, RV
MATTHIE, JR
WITHERS, PO
PETERSON, EL
ZAROWITZ, BJ
机构
[1] XITRON TECHNOL,DIV MED,SAN DIEGO,CA
[2] HENRY FORD HOSP,DIV BIOSTAT & EPIDEMIOL,DETROIT,MI 48202
[3] WAYNE STATE UNIV,COLL PHARM & ALLIED HLTH PROFESS,DETROIT,MI 48202
关键词
D O I
10.1177/106002809402800501
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: To determine the precision and bias of single- and multiple-frequency bioimpedance estimates of total body water (TBW) and extracellular water (ECW) volumes in comparison with die true values for these volumes established by gold standard dilution techniques. DESIGN: Controlled, prospective, open-label investigation. SETTING: Private, not-for-profit university-affiliated, acute care hospital. PARTICIPANTS: Normal, healthy men (n=8) and women (n=6) volunteers, 25-46 years of age. INTERVENTIONS: A single oral dose of a mixture of deuterium oxide 10 g and bromine 30 mmol; bioimpedance analysis pre- and hours postmixture administration. MAIN OUTCOME PARAMETERS: TBW and ECW volumes established by deuterium oxide and bromine dilutional spaces (gold standards), respectively, and single- and multiple-frequency bioimpedance estimates of those same volumes. RESULTS: The mean multiple-frequency bioimpedance (MFB) and single frequency bioimpedance (SFB) estimates of TBW, 41.2 and 42.1 L, respectively, were not statistically different (NS) from the 41.2 L deuterium oxide value. Although the two methods had similar precision (NS), MFB was less biased. For ECW, the mean MFB and SFB values of 19.5 and 24.8 L, respectively, were significantly different from the bromine value of 18.8 L (p=0.013 and p=0.001, respectively). MFB was the more precise and less biased predictor of ECW. CONCLUSIONS: Compared with SFB, the MFB approach is a more precise and less biased predictor of TBW and ECW volumes in young, healthy adults, and may offer more accurate assessment in subjects with aberrant physiology.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 22 条
[1]  
CHARLAND SL, 1989, CLIN PHARMACOL THER, V45, P131
[3]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[4]  
COTRAN RS, 1989, ROBBINS PATHOLOGIC B, P87
[5]  
Guyton A. C., 1986, TXB MED PHYSL, P382
[6]  
Hanai T, 1968, EMULSION SCI, P354
[7]   ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
KUSHNER, RF ;
SCHOELLER, DA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03) :417-424
[8]  
LOFGREN B, 1951, ACTA PHYSL SCAND, V23, P2
[10]   A SIMPLE, INEXPENSIVE METHOD OF DETERMINING TOTAL-BODY WATER USING A TRACER DOSE OF D2O AND INFRARED-ABSORPTION OF BIOLOGICAL-FLUIDS [J].
LUKASKI, HC ;
JOHNSON, PE .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 41 (02) :363-370