ADVANTAGES OF ENVIRONMENTAL SCANNING ELECTRON-MICROSCOPY IN STUDIES OF MICROORGANISMS

被引:59
作者
COLLINS, SP
POPE, RK
SCHEETZ, RW
RAY, RI
WAGNER, PA
LITTLE, BJ
机构
[1] UNIV SO MISSISSIPPI,DEPT BIOL SCI,HATTIESBURG,MS 39406
[2] USN,RES LAB DETACHMENT,BAY ST LOUIS,MS 39529
关键词
ENVIRONMENTAL SCANNING ELECTRON MICROSCOPY; ALGAE; FUNGI;
D O I
10.1002/jemt.1070250508
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Microorganisms, including bacteria, fungi, protozoa, and microalgae, are composed predominantly of water which prohibits direct observation in a traditional scanning electron microscope (SEM). Preparation for SEM requires that microorganisms be fixed, frozen or dehydrated, and coated with a conductive film before observation in a high vacuum environment. Sample preparation may mechanically disturb delicate samples, compromise morphological information, and introduce other artifacts. The environmental scanning electron microscope (ESEM) provides a technology for imaging hydrated or dehydrated biological samples with minimal manipulation and without the need for conductive coatings. Sporulating cultures of three fungi, Aspergillus sp., Cunninghamella sp., and Mucor sp., were imaged in the ESEM to assess usefulness of the instrument in the direct observation of delicate, uncoated, biological specimens. Asexual sporophores showed no evidence of conidial displacement or disruption of sporangia. Uncoated algal cells of Euglena gracilis and Spirogyra sp. were examined using the backscatter electron detector (BSE) and the environmental secondary electron detector (ESD) of the ESEM. BSE images had more clearly defined intracellular structures, whereas ESD gave a clearer view of the surface. E. gracilis cells fixed with potassium permanganate, Spirogyra sp. stained with Lugol's solution, and Saprolegnia sp. fixed with osmium tetroxide were compared using BSE and ESD to demonstrate that cellular details could be enhanced by the introduction of heavy metals. The effect of cellular water on signal quality was evaluated by comparing hydrated to critical point dried specimens. (C) 1993 Wiley-Liss, Inc.
引用
收藏
页码:398 / 405
页数:8
相关论文
共 10 条
[1]  
ABRAHAM JL, 1973, LANCET, V1, P1125
[2]   OBSERVATIONS ON FINE STRUCTURE OF PELLICLE PORES OF EUGLENA GRANULATA [J].
ARNOTT, HJ ;
WALNE, PL .
PROTOPLASMA, 1967, 64 (03) :330-&
[3]  
DANILATOS GD, 1988, ADV ELECTRON EL PHYS, V71, P109
[4]   A GASEOUS DETECTOR DEVICE FOR AN ENVIRONMENTAL SEM [J].
DANILATOS, GD .
MICRON AND MICROSCOPICA ACTA, 1983, 14 (04) :307-318
[5]   WIDE-BAND DETECTOR FOR MICRO-MICROAMPERE LOW-ENERGY ELECTRON CURRENTS [J].
EVERHART, TE ;
THORNLEY, RFM .
JOURNAL OF SCIENTIFIC INSTRUMENTS, 1960, 37 (07) :246-248
[6]   TECHNIQUE DE COLORATION HISTOLOGIQUE DE TISSUS INCLUS DANS DES POLYESTERS [J].
GAUTIER, A .
EXPERIENTIA, 1960, 16 (03) :124-124
[7]   OSMIOPHILIC REAGENTS - NEW CYTOCHEMICAL PRINCIPLE FOR LIGHT + ELECTRON MICROSCOPY [J].
HANKER, JS ;
BERGMAN, RA ;
WEISS, LP ;
SELIGMAN, AM ;
SEAMAN, AR ;
UENO, H .
SCIENCE, 1964, 146 (364) :1039-+
[8]   BIOFILMS - AN ESEM EVALUATION OF ARTIFACTS INTRODUCED DURING SEM PREPARATION [J].
LITTLE, B ;
WAGNER, P ;
RAY, R ;
POPE, R ;
SCHEETZ, R .
JOURNAL OF INDUSTRIAL MICROBIOLOGY, 1991, 8 (04) :213-221
[9]  
PARSONS TR, 1963, J MAR RES, V21, P155
[10]   ANALYSIS OF ERYTHROCYTE-MEDIATED MICROINJECTION BY BACKSCATTERED ELECTRON IMAGING [J].
ULRICH, RG ;
MCCLUNG, JK .
JOURNAL OF ULTRASTRUCTURE RESEARCH, 1983, 82 (03) :327-334