COMPARISON OF ASSISTED AND CONTROLLED MECHANICAL VENTILATION IN ANESTHETIZED SWINE

被引:4
作者
DOWNS, JB
DOUGLAS, ME
RUIZ, BC
MILLER, NL
机构
[1] UNIV FLORIDA, J HILLIS MILLER HLTH CTR, COLL VET MED, GAINESVILLE, FL 32610 USA
[2] VET ADM HOSP, GAINESVILLE, FL 32601 USA
关键词
D O I
10.1097/00003246-197901000-00002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We compared assisted mechanical ventilation with controlled mechanical ventilation with and without PEEP in 10 anesthetized swine. Catheters were placed to measure airway, intrapleural, and blood pressure; PaO2 and PaCO2; arterial pH; total minute ventilation; and mixed exhaled oxygen and carbon dioxide tensions. We calculated the ratio of physiological dead space to tidal volume, alveolar minute ventilation, CO2 production, VO2, and RQ. We found no clinically or statistically significant difference between assisted and controlled ventilation.
引用
收藏
页码:5 / 8
页数:4
相关论文
共 6 条
[1]   DEPRESSION OF CARDIAC OUTPUT WITH MECHANICAL VENTILATION - COMPARATIVE STUDIES OF INTERMITTENT POSITIVE POSITIVE-NEGATIVE AND ASSISTED VENTILATION [J].
ANDERSEN, MN ;
KUCHIBA, K .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1967, 54 (02) :182-&
[2]  
KIRBY R, 1972, ANESTH ANAL CURR RES, V51, P871
[3]   EFFECT OF VARYING INSPIRATORY GAS FLOW RATE [J].
KLEIN, M ;
HARRISON, VC ;
MALAN, AF ;
OWENTHOM.JB ;
ULAN, OA ;
SWYER, PR .
BRITISH JOURNAL OF ANAESTHESIA, 1969, 41 (04) :370-+
[4]   ASSISTED AND CONTROLLED VENTILATION IN NEWBORN PERIOD - EFFECT ON OXYGENATION [J].
LLEWELLYN, MA ;
SWYER, PR .
BRITISH JOURNAL OF ANAESTHESIA, 1971, 43 (10) :926-+
[5]  
SHAPIRO BA, 1975, CLIN APPLICATION RES, P316
[6]  
WILSON RD, 1973, AM SOC ANESTHESIOLOG, P121