A ROAD LESS TRAVELED - NORMAL PHASE MICROBORE LIQUID-CHROMATOGRAPHY - MASS-SPECTROMETRY USING DIRECT LIQUID INTRODUCTION

被引:9
作者
GARLAND, WA
HUSELTON, CA
KOLINSKY, F
LIBERATO, DJ
机构
关键词
D O I
10.1016/0165-9936(91)85018-M
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Despite many heroic attempts, no liquid chromatography-mass spectrometry (LC-MS) interface has, to date, approached the sensitivity routinely obtained by gas chromatography (GC)-MS, although the range of analytes possible with LC-MS is certainly greater. One of the first LC-MS interfaces developed was direct liquid introduction (DLI), but the utility of DLI in reversed-phase applications has been limited. However, excellent results have been obtained for certain compounds by combining normal phase, microbore LC with DLI. Of particular interest are results using DLI to analyze for retinoids, a biologically important class of compounds. Quantitation of endogenous tretinoin and isotretinoin in human plasma has been demonstrated using this technique.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 29 条
[1]  
APPFEL JA, 1983, ANAL CHEM, V55, P2280
[2]   THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLAKLEY, CR ;
VESTAL, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :750-754
[3]   GAS-CHROMATOGRAPHY NEGATIVE CHEMICAL IONIZATION MASS-SPECTROMETRY OF INTACT GLUCURONIDES [J].
BROWN, SY ;
GARLAND, WA ;
FUKUDA, EK .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (01) :32-36
[4]   RETINOIDS AS GENERALIZED REGULATORS OF CELLULAR GROWTH AND DIFFERENTIATION [J].
DAVIES, PJA ;
BASILION, JP ;
CHIOCCA, EA ;
JOHNSON, J ;
PODDAR, S ;
STEIN, JP .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1988, 296 (03) :164-170
[5]  
ECKERS C, 1982, CLIN CHEM, V28, P1882
[6]  
ECKHOFF C, 1990, J LIPID RES, V31, P1445
[7]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[8]   CONTINUOUS-FLOW FAST ATOM BOMBARDMENT LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - STUDIES INVOLVING CONVENTIONAL BORE LIQUID-CHROMATOGRAPHY WITH SIMULTANEOUS ULTRAVIOLET DETECTION [J].
GAMES, DE ;
PLEASANCE, S ;
RAMSEY, ED ;
MCDOWALL, MA .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (03) :179-182
[9]  
GAMES DE, 1986, ADV MASS SPECTROM B, V10, P323
[10]   DETERMINATION OF CLONAZEPAM IN HUMAN-PLASMA BY GAS CHROMATOGRAPHY NEGATIVE ION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GARLAND, WA ;
MIN, BH .
JOURNAL OF CHROMATOGRAPHY, 1979, 172 (APR) :279-286