APPLICABILITY OF ACTIVATED CARBON FELT TO THE DOSIMETRY OF SOLVENT VAPOR MIXTURE

被引:93
作者
HIRAYAMA, T
IKEDA, M
机构
[1] Department of Environmental Health, Tohoku University School of Medicine
来源
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL | 1979年 / 40卷 / 12期
关键词
D O I
10.1080/15298667991430749
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Affirmative results were obtained to prove that diffusion-absorption on carbon-desorption dosimetry is applicable to monitor exposure to mixed vapors of organic solvents (n-hexane: ethyl acetate: toluene = 1: 4: 1). While most of seven carbon felt preparations tested failed to absorb n-hexane in humid air or the amounts absorbed were no longer proportional to vapor concentrations even in dry air when the sum of the three vapor concentrations were over 3 times workroom threshold limits, two preparations revealed capacity to absorb n-hexane even in the air with relative humidity of 95%. Furthermore, the amounts absorbed during four hour exposures were linearly related to the vapor concentrations of at least 4.5 times workroom threshold limits when the three vapor concentrations were summed up, and, at lower concentrations, the absorbed amounts were proportional to the exposure duration of up to eight hours. Short term peak exposure could also be detected; the ratio between the observed and the expected was about 80% at lowest. Copyright 1979, American Industrial Hygiene Association
引用
收藏
页码:1091 / 1096
页数:6
相关论文
共 12 条
[1]  
BAILEY A, 1977, Annals of Occupational Hygiene, V20, P345, DOI 10.1093/annhyg/20.4.345
[2]   NEW PERSONAL SAMPLER FOR ORGANIC VAPORS [J].
BAMBERGER, RL ;
ESPOSITO, GG ;
JACOBS, BW ;
PODOLAK, GE ;
MAZUR, JF .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (09) :701-708
[3]  
EVANS M, 1977, Annals of Occupational Hygiene, V20, P357, DOI 10.1093/annhyg/20.4.357
[4]  
LEIDEL NA, 1975, STATISTICAL METHODS
[5]   DEVELOPMENT AND EVALUATION OF AN AMMONIA DOSIMETER [J].
MAZUR, JF ;
BAMBERGER, RL ;
PODOLAK, GE .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (09) :749-753
[6]   PERSONAL VINYL-CHLORIDE MONITORING DEVICE WITH PERMEATION TECHNIQUE FOR SAMPLING [J].
NELMS, LH ;
REISZNER, KD ;
WEST, PW .
ANALYTICAL CHEMISTRY, 1977, 49 (07) :994-998
[7]  
SILVERSTEIN LG, 1977, AM IND HYG ASSOC J, V38, P412
[8]   EVALUATION OF EXPOSURE TO ORGANIC-SOLVENT MIXTURE - COMPARATIVE STUDIES ON DETECTION TUBE AND GAS-LIQUID-CHROMATOGRAPHIC METHODS, PERSONAL AND STATIONARY SAMPLING, AND URINARY METABOLITE DETERMINATION [J].
TOKUNAGA, R ;
TAKAHATA, S ;
ONODA, M ;
ISHII, T ;
SATO, K ;
HAYASHI, M ;
IKEDA, M .
INTERNATIONALES ARCHIV FUR ARBEITSMEDIZIN, 1974, 33 (04) :257-267
[9]   NEW PERSONAL DOSIMETER FOR MONITORING OF INDUSTRIAL POLLUTANTS [J].
TOMPKINS, FC ;
GOLDSMITH, RL .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1977, 38 (08) :371-377
[10]  
1978, JAP J IND HLTH SANGY, V20, P290