SENSITIVE DETERMINATION OF JOSAMYCIN AND ROKITAMYCIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

被引:28
作者
TOD, M
BIAREZ, O
NICOLAS, P
PETITJEAN, O
机构
[1] Department of Pharmacotoxicology, Avicenne Hospital, 93000 Bobigny
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 575卷 / 01期
关键词
D O I
10.1016/0378-4347(92)80521-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rokitamycin and josamycin were successfully derivatized with dansylhydrazine in 20 min at 60-degrees-C. Rokitamycin and josamycin levels were determined in plasma after ion-pair extraction into hexane-isoamyl alcohol with lauryl sulphate and precolumn derivatization. Resolution was obtained by liquid chromatography with fluorescence detection (352/537 nm) in 12 min. The limit of detection was 20 ng/ml macrolide starting from 1 ml of plasma, and linearity was demonstrated between 50 and 400 ng/ml. Inter-run coefficients of variation were 10.2% at 100 ng/ml and 9.1% at 300 ng/ml. The system was reliably used for pharmacokinetic studies in plasma.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 11 条
[1]   1-DIMETHYLAMINONAPHTHALENE-5-SULFONYL HYDRAZINE (DANSYL HYDRAZINE) - FLUOROMETRIC REAGENT FOR CARBONYL COMPOUNDS [J].
CHAYEN, R ;
DVIR, R ;
GOULD, S ;
HARELL, A .
ANALYTICAL BIOCHEMISTRY, 1971, 42 (01) :283-&
[2]  
DUCCI M, 1984, INT J CLIN PHARM RES, V4, P195
[3]   FLUOROMETRIC HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROCORTISONE IN HUMAN-PLASMA [J].
GOEHL, TJ ;
SUNDARESAN, GM ;
PRASAD, VK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1979, 68 (11) :1374-1376
[4]   SENSITIVE ASSAY SYSTEM FOR BILE-ACIDS AND STEROIDS HAVING HYDROXYL-GROUPS UTILIZING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
HIGASHIDATE, S ;
HIBI, K ;
SENDA, M ;
KANDA, S ;
IMAI, K .
JOURNAL OF CHROMATOGRAPHY, 1990, 515 :577-584
[5]   SENSITIVE DETECTION OF OXO-STEROIDS AND OXO-BILE ACIDS BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION [J].
IMAI, K ;
HIGASHIDATE, S ;
NISHITANI, A ;
TSUKAMOTO, Y ;
ISHIBASHI, M ;
SHODA, J ;
OSUGA, T .
ANALYTICA CHIMICA ACTA, 1989, 227 (01) :21-27
[6]   DETERMINATION OF 17-OXOSTEROIDS IN SERUM AND URINE BY FLUORESCENCE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING DANSYL HYDRAZINE AS A PRE-LABELING REAGENT [J].
KAWASAKI, T ;
MAEDA, M ;
TSUJI, A .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01) :1-12
[7]   DETERMINATION OF TRACE LEVELS OF STEROIDS IN BLOOD-PLASMA BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION [J].
KOZIOL, T ;
GRAYESKI, ML ;
WEINBERGER, R .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :355-366
[8]  
MORISHITA M, 1984, CHEMOTHERAPY, V32, P70
[9]  
MORISHITA M, 1984, CHEMOTHERAPY TOKY S6, V32, P80
[10]  
SAUX MC, 1983, THERAPIE, V38, P591