Stress in Aerogel During Depressurization of Autoclave: II. Silica Gels

被引:31
作者
Woignier, Thierry [1 ]
Scherer, George W. [2 ]
Alaoui, Adil [1 ]
机构
[1] Univ Montpellier 2, Lab Sci Mat, F-34060 Montpellier, France
[2] Dupont Co, Wilmington, DE 19880 USA
关键词
aerogel; stress; drying; permeability; supercritical drying;
D O I
10.1007/BF00486720
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Although supercritical drying avoids the capillary stresses that tend to warp and crack xerogels, there are other sources of stress that interfere with the preparation of monolithic aerogels. In this paper, we present experimental results showing that there is a limit to the rate at which the pressure can be released from the autoclave without causing cracking, and that the maximum rate decreases as the gel size increases. Using an analysis developed in a companion paper, the stresses generated during depressurization are compared to the modulus of rupture of our aerogels. The calculations require knowledge of the pressure-dependence of the density of the vapor (ethanol, in our experiments), as well as the permeability and modulus of the gel network. Measurements of those properties were performed on a series of silica gels made under basic and neutral conditions. We find that the calculated stresses are large enough to account for the cracking of our gels at high rates of depressurization; moreover, the predicted dependence of stress on gel diameter is in agreement with experiment.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 17 条