DETERMINATION OF ALUMINUM IN THE HUMAN SERUM OF A DIALYSIS PATIENT BY ION-PAIR REVERSED-PHASE PARTITION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:53
作者
KANEKO, E
HOSHINO, H
YOTSUYANAGI, T
GUNJI, N
SATO, M
KIKUTA, T
YUASA, M
机构
[1] TOHOKU UNIV,FAC ENGN,DEPT MOLEC CHEM & ENGN,SENDAI,MIYAGI 980,JAPAN
[2] TOHOKU SPECIAL ANAL LABS,KORIYAMA 963,JAPAN
[3] TOMAKOMAI CLIN LAB,TOMAKOMAI 053,JAPAN
关键词
D O I
10.1021/ac00020a005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion-pair reversed-phase partition high-performance liquid chromatography-spectrophotometric method is described for the determination of aluminum in human serum, based on its complexation with 2,2'-dihydroxyazobenzene. The chelate is separated on C18-bonded silica packing by using a aqueous methanol mobile phase containing tetrabutylammonium bromide and is detected with 0.005 AU full-scale at 510 nm. The proposed system offers a simple, sensitive, and selective method. The detection limits defined as twice the standard deviation of the blank signal, are 0.2-mu-g L-1 in pure solution and 6-mu-g L-1 in serum. The sample solution is prepared from 0.4 mL of serum after protein precipitation with hydrochloric acid and methanol. There was good agreement between the values obtained by this method and graphite furnace atomic absorption spectrophotometry. The aluminum concentrations in 121 patients on hemodialysis were 6-201-mu-g L-1.
引用
收藏
页码:2219 / 2222
页数:4
相关论文
共 26 条
[1]  
ALDERMAN FR, 1980, CLIN CHEM, V26, P258
[2]  
BROWN S, 1984, CLIN CHEM, V30, P1216
[3]  
CANDY JM, 1986, LANCET, V1, P354
[4]   SEPARATION AND DETERMINATION OF ALUMINUM BY SINGLE-COLUMN ION-CHROMATOGRAPHY [J].
FORTIER, NE ;
FRITZ, JS .
TALANTA, 1985, 32 (11) :1047-1050
[5]   OPTIMIZATION OF THE ANALYTICAL CONDITIONS FOR THE DETERMINATION OF ALUMINUM IN HUMAN-BLOOD PLASMA OR SERUM BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY .1. EXAMINATION OF THE VARIOUS ANALYTICAL CONDITIONS [J].
GARDINER, PE ;
STOEPPLER, M ;
NURNBERG, HW .
ANALYST, 1985, 110 (06) :611-617
[6]  
HEWITT CD, 1990, CLIN CHEM, V36, P1466
[7]  
HOSHINO H, 1982, BUNSEKI KAGAKU, V31, pE435
[8]  
HOSHINO H, 1980, BUNSEKI KAGAKU, V29, P807
[9]   HIGHLY SELECTIVE DETERMINATION OF TRACE-METAL IONS WITH 2,2'-DIHYDROXYAZOBENZENE BY ION-PAIR REVERSED-PHASE PARTITION HPLC-SPECTROPHOTOMETRIC DETECTION SYSTEM [J].
HOSHINO, H ;
YOTSUYANAGI, T .
CHEMISTRY LETTERS, 1984, (08) :1445-1448
[10]   2,2'-DIHYDROXYAZOBENZENE DERIVATIVES AS REAGENTS FOR TRACE-METAL DETERMINATION BY ION-PAIR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH SPECTROPHOTOMETRIC DETECTION [J].
HOSHINO, H ;
NAKANO, K ;
YOTSUYANAGI, T .
ANALYST, 1990, 115 (02) :133-137