Objective - To determine whether a small fixed perioperative dose of warfarin would prevent deep vein thrombosis after total hip replacement. Design - Prospective, randomised, double blind placebo controlled trial. Setting - Winford Orthopaedic Hospital, Bristol. Subjects - 148 patients having primary total hip replacement. Intervention - Warfarin 1 mg given daily for one week before and three weeks after surgery. Main outcome measure - Deep vein thrombosis diagnosed by the iodine-125 labelled fibrinogen uptake method. Results - Deep vein thrombosis occurred in 25 (34%) of the patients given warfarin and 19 (26%) of the controls (difference 8%; 95% confidence interval -6.8% to 22.8%). Conclusion - Fixed minidose warfarin does not prevent deep vein thrombosis after total hip replacement.
引用
收藏
页码:219 / 220
页数:2
相关论文
共 14 条
[1]   THE POSTPHLEBITIC SYNDROME FOLLOWING SHAFT FRACTURES OF THE LEG - A SIGNIFICANT LATE COMPLICATION [J].
AITKEN, RJ ;
MILLS, C ;
IMMELMAN, EJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (05) :775-778
[2]  
BERGQVIST D, 1983, POSTOPERATIVE THROMB, P20
[3]  
BRENKEL I, 1989, BRIT J HOSP MED, V42, P282
[4]   THROMBOEMBOLISM AFTER TOTAL HIP RECONSTRUCTION - FAILURE OF LOW DOSES OF HEPARIN IN PREVENTION [J].
EVARTS, CM ;
ALFIDI, RJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1973, 225 (05) :515-516
[5]  
HAMPSON WGJ, 1974, LANCET, V2, P795
[6]   COMPARISON OF WARFARIN, LOW-MOLECULAR-WEIGHT DEXTRAN, ASPIRIN, AND SUBCUTANEOUS HEPARIN IN PREVENTION OF VENOUS THROMBOEMBOLISM FOLLOWING TOTAL HIP-REPLACEMENT [J].
HARRIS, WH ;
SALZMAN, EW ;
ATHANASOULIS, C ;
WALTMAN, AC ;
BAUM, S ;
DESANCTIS, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (08) :1552-1562
[7]   DETECTION OF PULMONARY EMBOLI AFTER TOTAL HIP-REPLACEMENT USING SERIAL (CO2)-O-15 PULMONARY SCANS [J].
HARRIS, WH ;
MCKUSICK, K ;
ATHANASOULIS, CA ;
WALTMAN, AC ;
STRAUSS, HW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (09) :1388-1393
[8]  
JOHNSON R, 1977, CLIN ORTHOP RELAT R, V127, P123
[9]  
KAKKAR VV, 1970, LANCET, V1, P540
[10]  
MAGNUSSEN P A, 1988, Journal of Bone and Joint Surgery British Volume, V70, P150