MR IMAGING OF JOINTS - ANALYTIC OPTIMIZATION OF GRE TECHNIQUES AT 1.5-T

被引:36
作者
YAO, L
SINHA, S
SEEGER, LL
机构
关键词
D O I
10.2214/ajr.158.2.1370362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To clarify the choice of imaging parameters for optimal gradient-recalled echo MR scanning of joints, we analyzed the behavior of contrast-to-noise and signal-to-noise ratios for spoiled (i.e., fast low-angle shot [FLASH] or spoiled GRASS) and steady-state (i.e., gradient-recalled acquisition in the steady state [GRASS] or fast imaging with steady precession) techniques at 1.5 T. The analysis is based on tissue characteristics derived from spin-echo measurements of hyaline cartilage and synovial fluid signal in the patellofemoral joints of 11 volunteers. Separate analysis of contrast-to-noise and signal-to-noise ratios for multiplanar (long TR) acquisitions shows that these parameters are each improved compared with single-slice methods. At TRs greater than 250 msec, there is no significant difference in the contrast behavior of FLASH and GRASS. For optimal contrast-to-noise ratio (synovial fluid-cartilage), the best multiplanar sequence (for TE < 23 msec) is with a short TE and a large flip angle (e.g., 400/9/73-degrees [TR/TE/flip angle]). If a single-scan or three-dimensional technique is desired, then a GRASS sequence at minimal TR and TE and intermediate flip angle (18/9/32-degrees) is best. For optimal signal-to-noise ratio (for both synovial fluid and hyaline cartilage), the best multiplanar sequence uses a short TE and an intermediate flip angle (e.g., 400/9/30-degrees). If a short TR, high signal-to-noise technique is desired, then GRASS (18/9/13-degrees) is superior to FLASH.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 9 条
[1]   DEGENERATIVE CARTILAGE LESIONS OF THE HIP - MAGNETIC-RESONANCE EVALUATION [J].
BONGARTZ, G ;
BOCK, E ;
HORBACH, T ;
REQUARDT, H .
MAGNETIC RESONANCE IMAGING, 1989, 7 (02) :179-186
[2]   CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING [J].
BUXTON, RB ;
EDELMAN, RR ;
ROSEN, BR ;
WISMER, GL ;
BRADY, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :7-16
[3]   PATELLAR CARTILAGE LESIONS - INVITRO DETECTION AND STAGING WITH MR IMAGING AND PATHOLOGICAL CORRELATION [J].
HAYES, CW ;
SAWYER, RW ;
CONWAY, WF .
RADIOLOGY, 1990, 176 (02) :479-483
[4]  
HOLT RG, 1990, SKELETAL RADIOL, V19, P5
[5]  
KONIG H, 1987, RADIOLOGY, V164, P753
[6]   A MODIFIED SATURATION RECOVERY APPROXIMATION FOR MULTIPLE SPIN-ECHO PULSE SEQUENCES [J].
LEE, JN ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (01) :132-134
[7]   STRUCTURE, FUNCTION, AND DEGENERATION OF BOVINE HYALINE CARTILAGE - ASSESSMENT WITH MR IMAGING INVITRO [J].
LEHNER, KB ;
RECHL, HP ;
GMEINWIESER, JK ;
HEUCK, AF ;
LUKAS, HP ;
KOHL, HP .
RADIOLOGY, 1989, 170 (02) :495-499
[8]   FAST FIELD ECHO IMAGING - AN OVERVIEW AND CONTRAST CALCULATIONS [J].
VANDERMEULEN, P ;
GROEN, JP ;
TINUS, AMC ;
BRUNTINK, G .
MAGNETIC RESONANCE IMAGING, 1988, 6 (04) :355-368
[9]   VARIATIONS IN SLICE SHAPE AND ABSORPTION AS ARTIFACTS IN THE DETERMINATION OF TISSUE PARAMETERS IN NMR IMAGING [J].
YOUNG, IR ;
BRYANT, DJ ;
PAYNE, JA .