MERSILENE (POLYESTER), A NEW SUTURE FOR PENETRATING KERATOPLASTY

被引:5
作者
RAMSELAAR, JAM [1 ]
BEEKHUIS, WH [1 ]
RIJNEVELD, WJ [1 ]
VANANDEL, MV [1 ]
DIJK, F [1 ]
JONGEBLOED, WL [1 ]
机构
[1] UNIV GRONINGEN, HISTOL & CELL BIOL LAB, 9700 AB GRONINGEN, NETHERLANDS
关键词
KERATOMETRIC ASTIGMATISM; MERSILENE SUTURE; NYLON SUTURE; PENETRATING KERATOPLASTY; SUTURE ADJUSTMENT; SCANNING ELECTRON MICROSCOPY;
D O I
10.1007/BF00156998
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Mersilene (polyester monofilament) seems to be suitable for penetrating keratoplasty because it is strong, shows no degradation by ultraviolet light, is insoluble, so that it can be left in situ, and offers the possibility of regulating postoperative astigmatism by suture adjustment. In 12 patients penetrating keratoplasty was performed with the combined interrupted/running suturing technique, using eight interrupted nylon 10-0 sutures and one running Mersilene 11-0 suture. The results were compared with those of 25 patients in whom eight interrupted nylon 10-0 sutures and one running nylon 11-0 suture were used. Six months after penetrating keratoplasty, no differences could be found between the two groups in keratometric astigmatism, visual acuity or slitlamp findings. In three patients postoperative adjustment of the running Mersilene suture reduced astigmatism by 50, 90 and 100% respectively. In an animal study the behaviour of Mersilene in the cornea was evaluated by slitlamp examination, histology and electron-microscopy. The tissue response to Mersilene was minimal. Considering the resemblance to nylon in clinical findings, minimal tissue response, lack of biodegradation and possibility of regulating postoperative astigmatism by suture adjustment, Mersilene seems to be a suitable material for penetrating keratoplasty.
引用
收藏
页码:89 / 101
页数:13
相关论文
共 15 条
[1]  
ARONSON SB, 1969, ARCH OPHTHALMOL-CHIC, V82, P531
[2]   ASTIGMATISM AFTER CATARACT-SURGERY - COMPARISON OF WOUND CLOSURE WITH NYLON AND MERSILENE [J].
BIGAR, F .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1990, 196 (05) :314-315
[3]  
BINDER PS, 1985, OPHTHALMOLOGY, V92, P1412
[4]  
COHAN BE, 1985, ARCH OPHTHALMOL-CHIC, V103, P1816
[5]   RUNNING NYLON SUTURE DISSOLUTION AFTER PENETRATING KERATOPLASTY [J].
FRUEH, BE ;
FELDMAN, ST ;
FELDMAN, RM ;
SOSSI, NP ;
FRUCHTPERY, J ;
BROWN, SI .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) :406-411
[6]   STAINLESS-STEEL AS SUTURING MATERIAL IN HUMAN CORNEAS AND RABBIT CORNEAS - A SEM-STUDY [J].
JONGEBLOED, WL ;
RIJNEVELD, WJ ;
CUPERUS, PL ;
VANANDEL, P ;
WORST, JGF .
DOCUMENTA OPHTHALMOLOGICA, 1988, 70 (2-3) :145-154
[7]   REACTION OF THE RABBIT CORNEAL ENDOTHELIUM TO NYLON SUTURES - A SEM STUDY [J].
JONGEBLOED, WL ;
VANDERVEEN, G ;
KALICHARAN, D ;
RIJNEVELD, WJ ;
HOUTMAN, WA ;
WORST, JGF .
DOCUMENTA OPHTHALMOLOGICA, 1990, 75 (3-4) :351-358
[8]  
Kelly S E, 1975, Ophthalmic Surg, V6, P105
[9]  
LIN DTC, 1990, OPHTHALMOLOGY, V97, P934
[10]  
McNeill J I, 1989, Refract Corneal Surg, V5, P216