摘要
A novel electrochemical stripping approach is presented for the trace measurement of arsenate. It is based on the reduction of As(V) in a mannitol and perchlorate containing solution, the coprecipitation with copper and the voltammetric determination by further reduction to AsH3 at the hanging mercury drop electrode. For an accumulation period of 60 s, the detection limit has been found to be 4.4 mu g/l; the determination limit was calculated to be 11 mu g/l. The method has been applied to the analysis of arsenic in a standard stream sediment and in water samples.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 17 条
[1]   TRACE DETERMINATION OF AS(III) AND AS(V) IN NATURAL-WATERS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
BODEWIG, FG ;
VALENTA, P ;
NURNBERG, HW .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 311 (03) :187-191
[2]   DETERMINATION OF ARSENITE AND ARSENATE BY DIFFERENTIAL PULSE POLAROGRAPHY [J].
CHAKRABORTI, D ;
NICHOLS, RL ;
IRGOLIC, KJ .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 319 (03) :248-251
[3]   DETERMINATION OF TOTAL ARSENIC AT NANOGRAM LEVEL BY HIGH-SPEED ANODIC-STRIPPING VOLTAMMETRY [J].
DAVIS, PH ;
DULUDE, GR ;
GRIFFIN, RM ;
MATSON, WR ;
ZINK, EW .
ANALYTICAL CHEMISTRY, 1978, 50 (01) :137-143
[4]   DETERMINATION OF ARSENIC BY ANODIC-STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
FORSBERG, G ;
OLAUGHLIN, JW ;
MEGARGLE, RG ;
KOIRTYOHANN, SR .
ANALYTICAL CHEMISTRY, 1975, 47 (09) :1586-1592
[5]  
FREHSE H, 1991, GIT FACHZ LAB, V4, P285
[6]   ELECTROCHEMICAL METHODS FOR THE DETERMINATION OF TOTAL ARSENIC AND ARSENIC COMPOUNDS [J].
GRESCHONIG, H ;
IRGOLIC, KJ .
APPLIED ORGANOMETALLIC CHEMISTRY, 1992, 6 (07) :565-577
[7]   DETERMINATION OF ARSENIC AND ANTIMONY IN ELECTROLYTIC COPPER BY ANODIC-STRIPPING VOLTAMMETRY AT A GOLD FILM ELECTRODE [J].
HAMILTON, TW ;
ELLIS, J ;
FLORENCE, TM .
ANALYTICA CHIMICA ACTA, 1980, 119 (02) :225-233
[8]   DETERMINATION OF ARSENIC IN THE SUB-PPB-RANGE BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY [J].
HENZE, G ;
JOSHI, AP ;
NEEB, R .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 300 (04) :267-272
[9]  
HENZE G, 1986, ELEKTROCHEMISCHE ANA, P185