EXPERIMENTAL-STUDY OF HUB CONTAMINATION - EFFECT OF A NEW CONNECTION DEVICE - THE I SYSTEM

被引:6
作者
INOUE, Y
NEZU, R
MATSUDA, H
FUJII, M
NAKAI, S
WASA, M
TAKAGI, Y
OKADA, A
机构
[1] OSAKA UNIV,SCH MED,DEPT PEDIAT SURG,1-1-50 FUKUSHIMA,FUKUSHIMA KU,OSAKA 553,JAPAN
[2] OSAKA UNIV,SCH MED,DEPT SURG 1,OSAKA 553,JAPAN
关键词
D O I
10.1177/0148607192016002178
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Experimental studies of hub contamination of intravenous catheters were done comparing the standard connection method (Luer-Lock connector) with a newly invented connection method (I system). Immersion of the connection sites into a bacteria-containing solution showed no bacterial contamination of the medium in any tubing. The second experiment investigated whether bacterial contamination would occur during a tubing change procedure. A high incidence of bacterial contamination was seen with the Luer-Lock connector, but no bacterial contamination occurred with the I system. These experiments suggest that the use of Luer-Lock connectors is associated with a high risk of bacterial contamination during tubing change, but the I system can prevent contamination during tubing change, which cannot be avoided with Luer-Lock connector.
引用
收藏
页码:178 / 180
页数:3
相关论文
共 13 条
[1]   AN OUTBREAK OF STAPHYLOCOCCUS-EPIDERMIDIS SEPTICEMIA [J].
DEITEL, M ;
KRAJDEN, S ;
SALDANHA, CF ;
GREGORY, WD ;
FUKSA, M ;
CANTWELL, E .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1983, 7 (06) :569-572
[2]  
DRYDEN GE, 1979, ANESTH ANALG, V58, P141
[3]   INVITRO CONTAMINATION OF PIGGYBACK HEPARIN LOCK ASSEMBLIES - PREVENTION OF CONTAMINATION WITH A CLOSED, POSITIVE LOCKING DEVICE (CLICK-LOCK) [J].
GIBILISCO, PA ;
LOPEZ, GA ;
APPLEMAN, MD ;
MILLBURG, WJ ;
KUSHELL, DL ;
ELOWITZ, L ;
JOHNSON, PA ;
ZENOWICH, D .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1986, 10 (04) :431-434
[4]  
HOLM I, 1975, ACTA CHIR SCAND, V141, P173
[5]   SEMIQUANTITATIVE CULTURE METHOD FOR IDENTIFYING INTRAVENOUS-CATHETER-RELATED INFECTION [J].
MAKI, DG ;
WEISE, CE ;
SARAFIN, HW .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (23) :1305-1309
[6]  
PEMBERTON LB, 1986, ARCH SURG-CHICAGO, V121, P591
[7]   RISK OF INFECTION ACCOMPANYING THE USE OF SINGLE-LUMEN VS DOUBLE-LUMEN SUBCLAVIAN CATHETERS - A PROSPECTIVE RANDOMIZED STUDY [J].
POWELL, C ;
FABRI, PJ ;
KUDSK, KA .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1988, 12 (02) :127-129
[8]   HUB COLONIZATION AS THE INITIAL STEP IN AN OUTBREAK OF CATHETER-RELATED SEPSIS DUE TO COAGULASE NEGATIVE STAPHYLOCOCCI DURING PARENTERAL-NUTRITION [J].
SITGESSERRA, A ;
PUIG, P ;
LINARES, J ;
PEREZ, JL ;
FARRERO, N ;
JAURRIETA, E ;
GARAU, J .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1984, 8 (06) :668-672
[9]  
SITGESSERRA A, 1985, SURGERY, V97, P355
[10]  
SITGESSERRA A, 1984, LANCET, V2, P459