VINYL MODIFICATION OF FUSED-SILICA SURFACES IN POLYSILOXANE-COATED 10-50 MU-M I D CAPILLARIES FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY

被引:5
作者
GOHLIN, K
LARSSON, M
机构
[1] ASTRA HASSLE AB,S-43183 MOLNDAL,SWEDEN
[2] CHALMERS UNIV TECHNOL,DEPT ANALYT & MARINE CHEM,S-41296 GOTHENBURG,SWEDEN
[3] GOTHENBURG UNIV,S-41296 GOTHENBURG,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 634卷 / 01期
关键词
D O I
10.1016/0021-9673(93)80309-V
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Attempts were made to improve the stability of narrow-bore open-tubular columns for liquid chromatography. In addition, the LC selectivity shift for thin stationary phase films was examined. Three different pretreatment methods based on vinyl-containing reagents were tested in 50 mum I.D. fused-silica capillaries. The modified capillaries were coated with the stationary phase PS 255, a polydimethylvinylsiloxane, and cross-linked. The columns were evaluated according to selectivity in LC and also to the degree of immobilization and column inertness in GC. Deactivating the capillaries with polydimethylvinylsiloxane was the preferred method. It was not possible to confirm bonding between the deactivation layer and the cross-linked polysiloxane stationary phase film. The proposal that the selectivity shift, for thin stationary phase films in open-tubular LC, originated from influence of the fused-silica surface on the stationary phase configuration could be excluded. The polydimethylvinylsiloxane method was also used in narrow-bore (10 mum I.D.) columns. Preliminary LC studies with anthracene derivatives as model substances indicated that deactivation has no influence on the efficiency.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 22 条
[1]   UNEXPECTED BEHAVIOR OF A COMMON GAS-CHROMATOGRAPHIC PHASE [J].
AUE, WA ;
HASTINGS, CR ;
KAPILA, S .
JOURNAL OF CHROMATOGRAPHY, 1973, 77 (02) :299-307
[2]   CHARACTERIZATION OF CHAIN BINDING TO FILLER IN SILICONE SILICA SYSTEMS [J].
COHENADDAD, JP ;
ROBY, C ;
SAUVIAT, M .
POLYMER, 1985, 26 (08) :1231-1233
[3]   PERFORMANCE AND PREPARATION OF IMMOBILIZED POLYSILOXANE STATIONARY PHASES IN 5-55 MU-M ID OPEN-TUBULAR FUSED-SILICA COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
JOSEFSSON, B ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (02) :347-372
[4]   LASER-INDUCED FLUORESCENCE DETECTION FOR CONVENTIONAL AND MICROCOLUMN LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
JOHNSON, L ;
JOSEFSSON, B ;
GALLE, B .
ANALYTICAL CHEMISTRY, 1982, 54 (06) :925-929
[5]  
FOLESTAD S, UNPUB
[6]   POLYORGANOSILOXANES .... SURFACE ACTIVE PROPERTIES [J].
FOX, HW ;
TAYLOR, PW ;
ZISMAN, WA .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1947, 39 (11) :1401-1409
[7]   NARROW (5-50-MU-M ID) OPEN TUBULAR COLUMNS IN LIQUID-CHROMATOGRAPHY USING IMMOBILIZED POLYMETHYL-OCTADECYLSILOXANE AS STATIONARY PHASE [J].
GOHLIN, K ;
LARSSON, M .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (06) :547-556
[8]  
GOHLIN K, UNPUB CHROMATOGRAPHI
[9]   COMPREHENSIVE, STANDARDIZED QUALITY TEST FOR GLASS CAPILLARY COLUMNS [J].
GROB, K ;
GROB, G ;
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1978, 156 (01) :1-20
[10]  
GROB K, 1981, J HIGH RES CHROMATOG, V4, P491