HEATED SAMPLE INTRODUCTION SYSTEM FOR THE ANALYSIS OF SLURRIES BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY

被引:17
作者
GERVAIS, LS [1 ]
SALIN, ED [1 ]
机构
[1] MCGILL UNIV,DEPT CHEM,801 SHERBROOKE ST W,MONTREAL H3A 2K6,QUEBEC,CANADA
关键词
SLURRY; SOLID SAMPLE INTRODUCTION; BABINGTON NEBULIZER; INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; HEATED SPRAY CHAMBER;
D O I
10.1039/ja9910600041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A slurry sample introduction system with a heated spray chamber followed by a condenser has been evaluated. Signal intensities (calibration curve slopes) increased for liquid standards by a factor of 11 while for solid (slurry) samples, intensities increased by a factor of approximately 3. Despite these intensity increases, detection limit improvements were marginal due to a comparable increase in noise. Experimentation demonstrated that it was necessary to use continuous tubular injector tube to reduce fluctuations in the plasma. Injector-gas composition appeared to have a major effect on the particle decomposition capability of the plasma.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 38 条
[1]  
Abercrombie F. N., 1977, ICP INFORM NEWSL, V2, P309
[2]   LASER ABLATION OF SOLIDS FOR ELEMENTAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ARROWSMITH, P .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1437-1444
[3]  
BEATY JS, 1984, J TEST EVAL, V12, P212
[4]   APPLICATION OF A WIRE LOOP DIRECT SAMPLE INSERTION DEVICE FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BOOMER, DW ;
POWELL, M ;
SING, RLA ;
SALIN, ED .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :975-976
[5]   LASER VAPORIZATION OF SOLID METAL SAMPLES INTO AN INDUCTIVELY COUPLED PLASMA [J].
CARR, JW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (01) :1-15
[6]   A FLUIDIZED-BED SAMPLING SYSTEM FOR THE DIRECT INTRODUCTION OF SOLIDS INTO AN INDUCTIVELY COUPLED PLASMA .1. PERFORMANCE-CHARACTERISTICS [J].
DESILVA, KN ;
GUEVREMONT, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (09) :865-874
[7]   DIRECT ANALYSIS OF SOIL SUSPENSIONS BY INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY FOR DETERMINATION OF TOTAL METALS [J].
DICK, WA ;
PAGE, JR ;
JEWELL, KE .
SOIL SCIENCE, 1985, 139 (03) :211-218
[8]   EMISSION SPECTROMETRIC DETECTION OF ELEMENTS AT NANOGRAM PER MILLILITER LEVEL USING INDUCTION-COUPLED PLASMA EXCITATION [J].
DICKINSON, GW ;
FASSEL, VA .
ANALYTICAL CHEMISTRY, 1969, 41 (08) :1021-+
[9]   PARTICLE-SIZE EFFECTS ON KAOLIN SLURRY ANALYSIS BY INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
EBDON, L ;
COLLIER, AR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (4-5) :355-369
[10]   ULTRASONIC NEBULIZATION OF LIQUID SAMPLES FOR ANALYTICAL INDUCTIVELY COUPLED PLASMA-ATOMIC SPECTROSCOPY - AN UPDATE [J].
FASSEL, VA ;
BEAR, BR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (10) :1089-1113