INSPIRATORY TO END-TIDAL OXYGEN DIFFERENCE DURING NITROUS-OXIDE ANESTHESIA

被引:6
作者
BENGTSON, JP
HARALDSSON, A
BENGTSSON, A
HENRIKSSON, BA
STENQVIST, O
机构
[1] Department of Anaesthesia and Intensive Care, Sahlgren Hospital, University of Göteborg
关键词
ANESTHESIA; GENERAL; ANESTHETICS; GASES; NITROUS OXIDE; MONITORING; INSPIRATORY-END TIDAL OXYGEN DIFFERENCE;
D O I
10.1093/bja/68.6.599
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
In order to evaluate the value of the inspiratory to end-tidal oxygen concentration difference (I(O2) - E'O2) as a monitor during general anaesthesia, we studied 40 orthopaedic patients allocated randomly to four groups: anaesthesia with enflurane or isoflurane in nitrous oxide with either spontaneous or controlled ventilation. (I(O2) - E'O2) followed an asymptotically increasing curve because of decreasing uptake of nitrous oxide. At 1 h, (I(O2) - E'O2) approached the end-tidal carbon dioxide concentration (E'CO2). During spontaneous ventilation, (I(O2) - E'O2) correlated best with E'CO2. During controlled ventilation, there was a negative correlation between (I(O2) - E'O2) and nitrous oxide uptake rate. Changes in oxygen uptake rate were reflected in (I(O2) - E'O2), provided that the total ventilation volume was constant and the nitrous oxide uptake rate approached steady state conditions.
引用
收藏
页码:599 / 602
页数:4
相关论文
共 5 条
[1]
GASEOUS HOMEOSTASIS DURING LOW-FLOW ANESTHESIA [J].
BENGTSON, JP ;
SONANDER, H ;
STENQVIST, O .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1988, 32 (07) :516-521
[2]
INSPIRATORY END-TIDAL OXYGEN-CONTENT DIFFERENCE - A SENSITIVE INDICATOR OF HYPOVENTILATION [J].
LINKO, K ;
PALOHEIMO, M .
CRITICAL CARE MEDICINE, 1989, 17 (04) :345-348
[3]
MONITORING OF THE INSPIRED AND END-TIDAL OXYGEN, CARBON-DIOXIDE, AND NITROUS-OXIDE CONCENTRATIONS - CLINICAL-APPLICATIONS DURING ANESTHESIA AND RECOVERY [J].
LINKO, K ;
PALOHEIMO, M .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (03) :149-156
[4]
A DIFFERENTIAL PARAMAGNETIC SENSOR FOR BREATH-BY-BREATH OXIMETRY [J].
MERILAINEN, PT .
JOURNAL OF CLINICAL MONITORING, 1990, 6 (01) :65-73
[5]
A FAST DIFFERENTIAL PARAMAGNETIC O-2-SENSOR [J].
MERILAINEN, PT .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1988, 5 (03) :187-195