HELICAL CT IMAGE NOISE ANALYTICAL RESULTS

被引:45
作者
WANG, G
VANNIER, MW
机构
[1] Division of Radiology Research, Mallinckrodt Institute of Radiology, Washington University Medical School, St. Louis, Missouri
关键词
COMPUTED TOMOGRAPHY; HELICAL SCANNING; SPIRAL SCANNING; LINEAR INTERPOLATION; NOISE;
D O I
10.1118/1.596950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Helical CT is an important recent development in x-ray CT. In helical CT, planar projection sets are synthesized from raw projection data via interpolation. Among various interpolation schemes, linear interpolation is usually preferred due to its efficiency and performance. In this paper, image noise variance is derived for typical helical CT linear interpolation techniques, including the full scan (FS), under-scan (US), full scan with interpolation (FI), half-scan (HS), half-scan with interpolation (HI) and half-scan with extrapolation (HE) methods. Image noise deviation ratios of helical CT to conventional 360-degrees reconstruction (CR) are tabulated. These are consistent with previously reported simulation results. The theoretical results provide further understanding of helical CT noise performance. It is shown that helical CT image noise deviation is independent of transaxial position, proportional to the raw projection noise deviation, and not affected by the fan angle (approximately for the HE method). Also, helical CT image noise variance is proportional to the area under the square of the reconstruction filter.
引用
收藏
页码:1635 / 1640
页数:6
相关论文
共 9 条
  • [1] [Anonymous], 1989, FUNDAMENTALS DIGITAL
  • [2] Bresler Y., 1989, P ICASSP, V3, P1472, DOI [10.1109/ICASSP.1989.266718, DOI 10.1109/ICASSP.1989.266718]
  • [3] SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE
    BRINK, JA
    HEIKEN, JP
    BALFE, DM
    SAGEL, SS
    DICROCE, J
    VANNIER, MW
    [J]. RADIOLOGY, 1992, 185 (02) : 469 - 474
  • [4] COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION
    CRAWFORD, CR
    KING, KF
    [J]. MEDICAL PHYSICS, 1990, 17 (06) : 967 - 982
  • [5] Kak AC, 1987, PRINCIPLES COMPUTERI
  • [6] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [7] PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING
    KALENDER, WA
    POLACIN, A
    [J]. MEDICAL PHYSICS, 1991, 18 (05) : 910 - 915
  • [8] EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT
    POLACIN, A
    KALENDER, WA
    MARCHAL, G
    [J]. RADIOLOGY, 1992, 185 (01) : 29 - 35
  • [9] INITIAL EXPERIENCE WITH VOLUME CT SCANNING
    RIGAUTS, H
    MARCHAL, G
    BAERT, AL
    HUPKE, R
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) : 675 - 682