MUSCULOSKELETAL NEOPLASMS - FAST LOW-ANGLE SHOT MR IMAGING WITH AND WITHOUT GD-DTPA

被引:22
作者
ERLEMANN, R
VASSALLO, P
BONGARTZ, G
MULLERMINY, H
RUMMENY, E
STOBER, U
PETERS, PE
机构
[1] Dept. of Clinical Radiology, Westfalische Wilhelms-Univ., 4400 Munster
关键词
D O I
10.1148/radiology.176.2.2367666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 121 patients, image contrast and contrast-to-noise ratios (C/Ns) obtained with gadolinium diethylenetriaminepentaacetic acid (DTPA)-enhanced and nonenhanced fast low-angle shot (FLASH) sequences were compared with those achieved with spin-echo (SE) sequences. Among FLASH sequences, contrast between neoplasms and muscle was sufficient with a flip angle of 90° following administration of Gd-DTPA but was 61% lower than that with the T2-weighted SE sequence. High contrast levels were obtained between tumors and bone marrow or fat in sclerotic, calcified, and fibrotic lesions with the use of a flip angle of 90° and in lytic lesions with a flip angle of 10°, reaching 66% of the contrast level obtained wiht the T1-weighted SE sequence. C/N between tumor and surrounding tissue was always significantly lower with FLASH sequences than with the ideal SE sequence usually used for tumor delineation. Thus, a replacement of the T2-weighted SE sequences by FLASH sequences cannot be recommended. A replacement of the T1-weighted SE sequences by FLASH sequences seems possible but does not significantly reduce examination time.
引用
收藏
页码:489 / 495
页数:7
相关论文
共 16 条
[1]   CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING [J].
BUXTON, RB ;
EDELMAN, RR ;
ROSEN, BR ;
WISMER, GL ;
BRADY, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :7-16
[2]   CERVICAL-SPINE - MR IMAGING WITH A PARTIAL FLIP ANGLE, GRADIENT-REFOCUSED PULSE SEQUENCE .2. SPINAL-CORD DISEASE [J].
ENZMANN, DR ;
RUBIN, JB .
RADIOLOGY, 1988, 166 (02) :473-478
[3]   CERVICAL-SPINE - MR IMAGING WITH A PARTIAL FLIP ANGLE, GRADIENT-REFOCUSED PULSE SEQUENCE .1. GENERAL-CONSIDERATIONS AND DISK DISEASE [J].
ENZMANN, DR ;
RUBIN, JB .
RADIOLOGY, 1988, 166 (02) :467-472
[4]   MUSCULOSKELETAL NEOPLASMS - STATIC AND DYNAMIC GD-DTPA ENHANCED MR IMAGING [J].
ERLEMANN, R ;
REISER, MF ;
PETERS, PE ;
VASALLO, P ;
NOMMENSEN, B ;
KUSNIERZGLAZ, CR ;
RITTER, J ;
ROESSNER, A .
RADIOLOGY, 1989, 171 (03) :767-773
[5]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[6]  
KONIG H, 1986, FORTSCHR RONTG NEUEN, V145, P307
[7]  
KONIG H, 1987, RADIOLOGY, V164, P753
[8]   CERVICAL-SPINE MR IMAGING USING MULTISLICE GRADIENT ECHO IMAGING - COMPARISON WITH CARDIAC GATED SPIN-ECHO [J].
KULKARNI, MV ;
NARAYANA, PA ;
MCARDLE, CB ;
YEAKLEY, JW ;
CAMPAGNA, NF ;
WEHRLI, FW .
MAGNETIC RESONANCE IMAGING, 1988, 6 (05) :517-525
[9]   PARTIAL FLIP ANGLE MR IMAGING [J].
MILLS, TC ;
ORTENDAHL, DA ;
HYLTON, NM ;
CROOKS, LE ;
CARLSON, JW ;
KAUFMAN, L .
RADIOLOGY, 1987, 162 (02) :531-539
[10]  
OPPELT A, 1986, Electromedica (English Edition), V54, P15