CAPILLARY ISOELECTRIC-FOCUSING WITH IMAGING DETECTION

被引:20
作者
WU, JQ [1 ]
PAWLISZYN, J [1 ]
机构
[1] UNIV WATERLOO,DEPT CHEM,WATERLOO N2L 3G1,ONTARIO,CANADA
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 9-10期
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1080/10826079308019904
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple on-line absorbance imaging detection system was constructed for detection of capillary isoelectric focusing (CIEF). Because of the use of the CIEF-imaging detection system, separation and detection of protein sample could be completed in 2 minutes. The use of the imaging detection system also allowed for studying the focusing process. When a 4 cm long, 200-mum i. d. square capillary was used as the separation column, the concentration detection limit of the detector reached 5 mug/Ml. This is the first report of applying absorbance imaging detection system to capillary electrophoretic techniques. The absorbance imaging detection system was compared with the refractive index gradient imaging detection system. For the capillary with large i. d., the absorbance imaging system showed higher sensitivity than the refractive index gradient imaging detector. However, the refractive index gradient imaging system was more suitable for narrow capillaries because it applied a laser as the light source which could be easily focused into narrow capillaries. The sensitivity of the refractive index gradient imaging detector was expected to be higher for narrower capillaries than the absorbance imaging detector.
引用
收藏
页码:1891 / 1902
页数:12
相关论文
共 14 条
[1]   CHARACTERIZATION OF HUMANIZED ANTI-TAC MONOCLONAL-ANTIBODY BY TRADITIONAL SEPARATION TECHNIQUES AND CAPILLARY ELECTROPHORESIS [J].
COSTELLO, MA ;
WOITITZ, C ;
DEFEO, J ;
STREMLO, D ;
WEN, LFL ;
PALLING, DJ ;
IQBAL, K ;
GUZMAN, NA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1081-1097
[2]   DETERMINATION OF PI BY MEASURING THE CURRENT IN THE MOBILIZATION STEP OF HIGH-PERFORMANCE CAPILLARY ISOELECTRIC-FOCUSING - ANALYSIS OF TRANSFERRIN FORMS [J].
KILAR, F .
JOURNAL OF CHROMATOGRAPHY, 1991, 545 (02) :403-406
[3]   FAST AND HIGH-RESOLUTION ANALYSIS OF HUMAN-SERUM TRANSFERRIN BY HIGH-PERFORMANCE ISOELECTRIC-FOCUSING IN CAPILLARIES [J].
KILAR, F ;
HJERTEN, S .
ELECTROPHORESIS, 1989, 10 (01) :23-29
[4]   CAPILLARY ISOELECTRIC-FOCUSING - EFFECTS OF CAPILLARY GEOMETRY, VOLTAGE GRADIENT AND ADDITION OF LINEAR POLYMER [J].
THORMANN, W ;
TSAI, A ;
MICHAUD, JP ;
MOSHER, RA ;
BIER, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 389 (01) :75-86
[5]   EXPERIMENTAL AND THEORETICAL DYNAMICS OF ISOELECTRIC-FOCUSING - ELUCIDATION OF A GENERAL SEPARATION MECHANISM [J].
THORMANN, W ;
MOSHER, RA ;
BIER, M .
JOURNAL OF CHROMATOGRAPHY, 1986, 351 (01) :17-29
[6]   WHOLE COLUMN ABSORBENCY DETECTION IN CAPILLARY ISOELECTRIC-FOCUSING [J].
WANG, TS ;
HARTWICK, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (15) :1745-1747
[7]  
WEHR T, 1990, AM BIOTECHNOL LAB, V8, P22
[8]  
WU J, 1993, IN PRESS ELECTROPHOR, V14
[9]  
WU J, 1992, IN PRESS APPL SPECTR, V46
[10]  
WU J, 1992, IN PRESS ANAL CHEM, V64