ONE GONIOSCOPIC FALLACY

被引:7
作者
MAPSTONE, R
机构
关键词
D O I
10.1136/bjo.63.4.221
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Traditional gonioscopic practice assumes that, if most of the angle is gonioscopically closed, intraocular pressure increases. Evidence is produced to show that this is fallacious, because at its inception angle closure is iridocorneal contact occurring on the corneal side of the limbus. Although the angle cannot be seen by means of a gonioscope, there is initially no iridotrabecular contact. It is only after pressure increases that iris is pushed against trabecular meshwork and the angle is truly closed.
引用
收藏
页码:221 / 224
页数:4
相关论文
共 3 条
[1]  
Becker B, 1961, DIAGNOSIS THERAPY GL
[2]  
DUKEELDER S, 1969, DISEASES LENS VITREO
[3]   PARTIAL ANGLE CLOSURE [J].
MAPSTONE, R .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1977, 61 (08) :525-530