ASSESSMENT OF ACCURACY AND ANALYSIS TIME OF A NOVEL DEVICE TO MONITOR SLEEP AND BREATHING IN THE HOME

被引:100
作者
WHITE, DP
GIBB, TJ
WALL, JM
WESTBROOK, PR
机构
[1] UNIV COLORADO,DIV PULM,DENVER,CO 80202
[2] CEDARS SINAI MED CTR,LOS ANGELES,CA 90048
关键词
SLEEP; APNEA; HOME MONITORING; POLYSOMNOGRAPHY;
D O I
10.1093/sleep/18.2.115
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Obstructive sleep apnea is increasingly recognized as a common and debilitating disorder. As a result, a variety of diagnostic technologies have evolved to potentially decrease cost and improve access and ease of assessment, In this study we compared the Healthdyne NightWatch (NW) System (a home sleep diagnostic methodology) to standard polysomnography (PSC) in two sleep centers. Two separate studies were completed. NW was compared to a simultaneously obtained PSG in 30 patients (IN-LAB study). Seventy additional patients were studied in both the home with NW and in the laboratory with PSG (HOME-LAB study). The NW system records eye movement, leg movement, SaO(2), nasal-oral airflow, chest and abdominal wall motion, body position and heart rate on a solid state recorder, which permits sleep staging based on body and eye movement and standard respiratory assessment. For the PSG, standard paper recording techniques were used. The IN-LAB study revealed a correlation between NW and PSG for total sleep time of r = 0.72, with NW tending to score some awake time as nonrapid eye movement sleep. The correlation for apnea-hypopnea index (AHI) was r = 0.94 between systems, with a sensitivity of 100% and specificity of 63.6% at an AHI threshold of 10. The HOME-LAB study demonstrated understandably poor correlations between NW and PSG for most measures of sleep, which is likely a product of night-to-night variability in sleep, home versus laboratory effects and the differences in sleep staging methodology. However, the correlation for AHI was r = 0.92, with a sensitivity of 90.7% and a specificity of 70.4% at an AHI threshold of 10. Using a new methodology to assess agreement between diagnostic systems, we observed 78.6% diagnostic agreement between NW and PSG in the HOME-LAB study, with NW underestimating AHI 4.3% of the time and overestimating it in 17.1% of cases. This may relate to night-to-night variability in AHI or greater NW computer sensitivity to subtle hypopneas. We conclude that NW provides an accurate determination of AHI in both the home and laboratory, using limited instrumentation. The analysis time for NW is also reduced compared to PSG, and patients generally prefer the NW evaluation.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 23 条
[1]  
ALLAN M A, 1990, American Review of Respiratory Disease, V141, pA858
[2]  
ANCOLIISRAEL S, 1981, SLEEP, V4, P283
[3]   MENOPAUSE, MEDROXYPROGESTERONE AND BREATHING DURING SLEEP [J].
BLOCK, AJ ;
WYNNE, JW ;
BOYSEN, PG ;
LINDSEY, S ;
MARTIN, C ;
CANTOR, B .
AMERICAN JOURNAL OF MEDICINE, 1981, 70 (03) :506-510
[4]   CLINICAL-VALUE OF POLYSOMNOGRAPHY [J].
DOUGLAS, NJ ;
THOMAS, S ;
JAN, MA .
LANCET, 1992, 339 (8789) :347-350
[5]   VERIFICATION OF SLEEP-APNEA USING A PORTABLE SLEEP-APNEA SCREENING DEVICE [J].
EMSELLEM, HA ;
CORSON, WA ;
RAPPAPORT, BA ;
HACKETT, S ;
SMITH, LG ;
HAUSFELD, JN .
SOUTHERN MEDICAL JOURNAL, 1990, 83 (07) :748-752
[6]   AUTOMOBILE ACCIDENTS INVOLVING PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA [J].
FINDLEY, LJ ;
UNVERZAGT, ME ;
SURATT, PM .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 138 (02) :337-340
[7]   UNDIAGNOSED SLEEP-APNEA IN PATIENTS WITH ESSENTIAL-HYPERTENSION [J].
FLETCHER, EC ;
DEBEHNKE, RD ;
LOVOI, MS ;
GORIN, AB .
ANNALS OF INTERNAL MEDICINE, 1985, 103 (02) :190-195
[8]   EVALUATION OF A MICROPROCESSOR-BASED PORTABLE HOME MONITORING-SYSTEM TO MEASURE BREATHING DURING SLEEP [J].
GYULAY, S ;
GOULD, D ;
SAWYER, B ;
POND, D ;
MANT, A ;
SAUNDERS, N .
SLEEP, 1987, 10 (02) :130-142
[9]   MORTALITY AND APNEA INDEX IN OBSTRUCTIVE SLEEP-APNEA - EXPERIENCE IN 385 MALE-PATIENTS [J].
HE, J ;
KRYGER, MH ;
ZORICK, FJ ;
CONWAY, W ;
ROTH, T .
CHEST, 1988, 94 (01) :9-14
[10]  
HOELSCHER TJ, 1989, SLEEP, V12, P133