A NORMALIZATION TECHNIQUE FOR 3D PET DATA

被引:76
作者
DEFRISE, M
TOWNSEND, DW
BAILEY, D
GEISSBUHLER, A
MICHEL, C
JONES, T
机构
[1] UNIV GENEVA,HOP CANTONAL,DIV NUCL MED,CH-1211 GENEVA 4,SWITZERLAND
[2] HAMMERSMITH HOSP,MRC,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
[3] POSITRON TOMOG LAB,LOUVAINA LA NEUVE,BELGIUM
关键词
D O I
10.1088/0031-9155/36/7/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prior to reconstruction, emission data from a multi-ring PET camera must be corrected (normalized) for variations in detector sensitivity. The appropriate correction coefficients are obtained by measuring the response of all coincidence lines to a calibrated source of activity (a blank scan). State-of-the-art cameras may contain up to a million such lines of response (LORs), and therefore around 400 million counts will be required to calibrate each LOR to a statistical accuracy of 5%. Alternatively, by modelling the LOR sensitivity as the product of the individual detector efficiencies and a geometrical factor, a calibration procedure has been proposed which requires the determination of only 6000 parameters from this same data set. A significant improvement in the statistical accuracy of the coefficients can therefore be expected. Recently, multi-ring scanners have been operated with the septa retracted, increasing the number of measured LORs by a factor of eight. The acquisition of the calibration data necessary to achieve adequate statistical accuracy then becomes prohibitive. We show that, by modelling the LOR sensitivity, it is possible, with certain approximations, to normalize a septa-retracted emission data set with good accuracy. The input to the model is a high statistics blank scan acquired with the septa extended, which offers a number of practical advantages.
引用
收藏
页码:939 / 952
页数:14
相关论文
共 8 条
[1]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[2]  
CASEY ME, 1990, COMMUNICATION
[3]   A STUDY OF THE POSSIBILITY OF USING MULTI-SLICE PET SYSTEMS FOR 3D IMAGING [J].
DAHLBOM, M ;
ERIKSSON, L ;
ROSENQVIST, G ;
BOHM, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1066-1071
[4]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[5]  
THOMPSON C, 1988, IEEE T NUCL SCI, V36, P598
[6]   ASPECTS OF 3 DIMENSIONAL RECONSTRUCTION FOR A MULTI RING POSITRON TOMOGRAPH [J].
TOWNSEND, D ;
SPINKS, T ;
JONES, T ;
GEISSBUHLER, A ;
DEFRISE, M ;
GILARDI, MC ;
HEATHER, J .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :741-745
[7]   3 DIMENSIONAL RECONSTRUCTION OF PET DATA FROM A MULTI-RING CAMERA [J].
TOWNSEND, DW ;
SPINKS, T ;
JONES, T ;
GEISSBUHLER, A ;
DEFRISE, M ;
GILARDI, MC ;
HEATHER, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1056-1065
[8]  
TOWNSEND DW, 1991, IN PRESS IEEE T MED