SPATIAL HETEROGENEITY IN NORMAL SKIN PERFUSION RECORDED WITH LASER-DOPPLER IMAGING AND FLOWMETRY

被引:103
作者
WARDELL, K
BRAVERMAN, IM
SILVERMAN, DG
NILSSON, GE
机构
[1] YALE UNIV,SCH MED,DEPT DERMATOL,NEW HAVEN,CT 06510
[2] YALE UNIV,SCH MED,DEPT ANESTHESIOL,NEW HAVEN,CT 06510
关键词
D O I
10.1006/mvre.1994.1036
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Spatial and temporal variations in forearm skin perfusion captured by laser Doppler perfusion imaging (LDI) have been compared with topographic maps recorded by laser Doppler flowmetry. In order to determine the shortest LDI sampling time required at each measurement site, with an adequate signal-to-noise ratio and with the ability to display the heterogeneity in skin perfusion, the noise-limited resolution of the LDI system as well as various sampling times were tested. The noise-limited resolution for medium and high light intensities were less than 0.5% (temporal) and 0.3% (spatial) of full scale. A sampling time of 1 sec was selected and image presentation was made by performing bilinear interpolation between perfusion values. The same area (10 x 10 mm) was mapped with LDI and topographic mapping at seven different sites. In addition, a larger area covering the surrounding skin was recorded with LDI. The small area recordings with LDI and topographic mapping could be identified in the larger LDI image. High-and low-perfusion spots coincided between the two systems. Temporal variations were studied by repeated LDI recordings of the same areas as above. Small spots were selected in the areas and plotted versus time. Without provocation, the total perfusion changes at each spot showed large variations, but the relative perfusion levels between neighboring spots persisted. Provocation with heat increased the perfusion in all spots. (C) 1994 Academic Press, Inc.
引用
收藏
页码:26 / 38
页数:13
相关论文
共 12 条
[1]   THE EFFECT OF SPINAL ANALGESIA ON SKIN BLOOD-FLOW, EVALUATED BY LASER DOPPLER FLOWMETRY [J].
BENGTSSON, M ;
NILSSON, GE ;
LOFSTROM, JB .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1983, 27 (03) :206-210
[2]   CORRELATION OF LASER DOPPLER WAVE PATTERNS WITH UNDERLYING MICROVASCULAR ANATOMY [J].
BRAVERMAN, IM ;
KEH, A ;
GOLDMINZ, D .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1990, 95 (03) :283-286
[3]   CONTOUR MAPPING OF THE CUTANEOUS MICROVASCULATURE BY COMPUTERIZED LASER DOPPLER VELOCIMETRY [J].
BRAVERMAN, IM ;
SCHECHNER, JS .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1991, 97 (06) :1013-1018
[4]   TOPOGRAPHIC MAPPING OF THE CUTANEOUS MICROCIRCULATION USING 2 OUTPUTS OF LASER-DOPPLER FLOWMETRY - FLUX AND THE CONCENTRATION OF MOVING BLOOD-CELLS [J].
BRAVERMAN, IM ;
SCHECHNER, JS ;
SILVERMAN, DG ;
KEHYEN, A .
MICROVASCULAR RESEARCH, 1992, 44 (01) :33-48
[5]   PREDICTION OF SAMPLING DEPTH AND PHOTON PATHLENGTH IN LASER-DOPPLER FLOWMETRY [J].
JAKOBSSON, A ;
NILSSON, GE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) :301-307
[6]   REPEATED MEASUREMENT VARIATION AND PRECISION OF LASER DOPPLER FLOWMETRY MEASUREMENTS [J].
LINE, PD ;
MOWINCKEL, P ;
LIEN, B ;
KVERNEBO, K .
MICROVASCULAR RESEARCH, 1992, 43 (03) :285-293
[7]   NEW INSTRUMENT FOR CONTINUOUS MEASUREMENT OF TISSUE BLOOD-FLOW BY LIGHT BEATING SPECTROSCOPY [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (01) :12-19
[8]   EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) :597-604
[9]   INTEGRATING PROBE FOR TISSUE LASER DOPPLER FLOWMETERS [J].
SALERUD, EG ;
NILSSON, GE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (04) :415-419
[10]   EVALUATION OF AN INFRARED LASER-DOPPLER BLOOD FLOWMETER [J].
SHEPHERD, AP ;
RIEDEL, GL ;
KIEL, JW ;
HAUMSCHILD, DJ ;
MAXWELL, LC .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06) :G832-G839