AN ACCURATE TECHNIQUE FOR DETAILED PROSTATIC INTERSTITIAL TEMPERATURE-MAPPING IN PATIENTS RECEIVING MICROWAVE THERMAL-TREATMENT

被引:30
作者
LARSON, TR [1 ]
COLLINS, JM [1 ]
机构
[1] MAYO CLIN, DEPT DIAGNOST RADIOL, SCOTTSDALE, AZ 85259 USA
关键词
D O I
10.1089/end.1995.9.339
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
A minimally invasive prostatic interstitial temperature-mapping technique is described that supplies accurate, detailed information on thermal doses delivered to precisely localized tissue sites, The technique employs a comparatively large numbers of thermosensors, highly accurate placement of those thermosensors at specified three-dimensional coordinates, fiberoptic technology that avoids significant interaction between the thermosensors and the applied microwave field, and continuous temperature readout, Biplane ultrasound imaging and fluoroscopy were used to ensure stereotactic accuracy of thermosensor placement, The technique was applied in 15 patients with benign prostatic hyperplasia (BPH) undergoing a 1-hour microwave thermal treatment session, The thermal mapping procedures and microwave treatment were generally well tolerated, The mean maximum temperature in the prostate and periprostatic tissue (57.9 +/- 1.9 degrees C) was significantly higher (P < 0.001) by more than 18 degrees C than that in either the urethra (39.6 +/- 0.9 degrees C) or the rectum (40.8 +/- 1.7 degrees C), In a representative patient, microwave treatment resulted in stable elevation of temperature 5 mm radially from the urethra that averaged 66.0 +/- 0.1 degrees C, At 10 mm from the urethra, the temperature averaged 50.5 +/- 0.1 degrees C, Urethral and rectal temperatures remained at innocuous levels, In conjunction with pathologic studies, this interstitial thermal mapping method should prove useful in defining the optimal thermal doses for microwave therapy, The method should also find uses in evaluating different microwave treatment systems, which can vary markedly in thermal performance, as well as other modalities that apply heat to prostatic tissue.
引用
收藏
页码:339 / 347
页数:9
相关论文
共 19 条
[1]   PHASE I/II STUDY OF EXTERNAL RADIO-FREQUENCY PHASED-ARRAY HYPERTHERMIA AND EXTERNAL BEAM RADIOTHERAPY IN THE TREATMENT OF PROSTATE-CANCER - TECHNIQUE AND RESULTS OF INTRAPROSTATIC TEMPERATURE-MEASUREMENTS [J].
ANSCHER, MS ;
SAMULSKI, TV ;
LEOPOLD, KA ;
OLESON, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (03) :489-495
[2]   HEATING CHARACTERISTICS OF A HELICAL MICROWAVE APPLICATOR FOR TRANSURETHRAL HYPERTHERMIA OF BENIGN PROSTATIC HYPERPLASIA [J].
ASTRAHAN, M ;
IMANAKA, K ;
JOZSEF, G ;
AMEYE, F ;
BAERT, L ;
SAPOZINK, MD ;
BOYD, S ;
PETROVICH, Z .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1991, 7 (01) :141-155
[3]   INTERSTITIAL TEMPERATURE-MEASUREMENTS DURING TRANSURETHRAL MICROWAVE HYPERTHERMIA [J].
ASTRAHAN, MA ;
AMEYE, F ;
OYEN, R ;
WILLEMEN, P ;
BAERT, L ;
PETROVICH, Z .
JOURNAL OF UROLOGY, 1991, 145 (02) :304-308
[4]   TRANSURETHRAL HYPERTHERMIA FOR BENIGN PROSTATIC HYPERPLASIA PATIENTS WITH RETENTION [J].
BAERT, L ;
AMEYE, F ;
PIKE, MC ;
WILLEMEN, P ;
ASTRAHAN, MA ;
PETROVICH, Z .
JOURNAL OF UROLOGY, 1992, 147 (06) :1558-1561
[5]   TRANSURETHRAL MICROWAVE TREATMENT FOR BENIGN PROSTATIC HYPERTROPHY - A RANDOMIZED CONTROLLED CLINICAL-TRIAL [J].
BDESHA, AS ;
BUNCE, CJ ;
KELLEHER, JP ;
SNELL, ME ;
VUKUSIC, J ;
WITHEROW, RO .
BRITISH MEDICAL JOURNAL, 1993, 306 (6888) :1293-1296
[6]   THE DEVELOPMENT OF HUMAN BENIGN PROSTATIC HYPERPLASIA WITH AGE [J].
BERRY, SJ ;
COFFEY, DS ;
WALSH, PC ;
EWING, LL .
JOURNAL OF UROLOGY, 1984, 132 (03) :474-479
[7]  
BLASKO JC, 1991, SCAND J UROL NEPHROL, P113
[8]  
BOSTWICK DG, 1995, IN PRESS PROSTATE
[9]   TRANSRECTAL ULTRASOUND-GUIDED INTERSTITIAL RADIATION-THERAPY FOR LOCALIZED PROSTATE-CANCER [J].
BROSMAN, SA ;
TOKITA, K .
UROLOGY, 1991, 38 (04) :372-376
[10]   TEMPERATURE STEERING IN PROSTATE BY SIMULTANEOUS TRANSURETHRAL AND TRANSRECTAL HYPERTHERMIA [J].
DEBICKI, P ;
ASTRAHAN, MA ;
AMEYE, F ;
OYEN, R ;
BAERT, L ;
HACZEWSKI, A ;
PETROVICH, Z .
UROLOGY, 1992, 40 (04) :300-307