EXPERIMENTAL RETINAL EMBOLISM - STUDIES WITH HIGH SPEED FLUORESCEIN CINEMATOGRAPHY

被引:31
作者
KULVIN, SM
DAVID, NJ
机构
关键词
D O I
10.1001/archopht.1967.00980030776016
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Retinal embolis''m, produced in the owl monkey with autologous fibrin clot was studied by high speed fluorescein cinematography. The pattern of retrograde collateral flow was followed. Emboli were often observed in the retinal arteries in contrast studies. Endothelial damage manifested by fluorescein leakage from arteries may be caused by passage of the febrin clot.
引用
收藏
页码:774 / +
相关论文
共 14 条
[1]  
[Anonymous], 1966, BRIT J OPHTHALMOL
[2]  
Dollery C T, 1965, Trans Ophthalmol Soc U K, V85, P271
[3]  
DOLLERY CT, 1965, LANCET, V1, P1303
[4]  
GAY AJ, 1964, INVEST OPHTH VISUAL, V3, P647
[5]  
GOLDOR HOWARD, 1967, INVEST OPHTHALMOL, V6, P51
[6]  
HART LM, 1963, J LAB CLIN MED, V62, P703
[7]   BALLOTINI OCCLUSION OF RETINAL ARTERIES - COLLATERAL VESSELS [J].
HENKIND, P .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1966, 50 (08) :482-&
[8]  
HENKIND P, 1966, INVEST OPHTHALMOL, V5, P204
[9]   IMPROVED METHOD FOR FLUORESCENCE ANGIOGRAPHY OF RETINA [J].
HODGE, JV ;
CLEMETT, RS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1966, 61 (06) :1400-&
[10]  