LASER GUIDANCE-SYSTEM FOR CT-GUIDED PROCEDURES

被引:22
作者
MIAUX, Y [1 ]
GUERMAZI, A [1 ]
GOSSOT, D [1 ]
BOURRIER, P [1 ]
ANGOULVANT, D [1 ]
KHAIROUNE, A [1 ]
TURKI, C [1 ]
BOUCHE, E [1 ]
机构
[1] HOP ST LOUIS,DEPT SURG,F-75011 PARIS,FRANCE
关键词
BIOPSIES; TECHNOLOGY; COMPUTED TOMOGRAPHY (CT) GUIDANCE;
D O I
10.1148/radiology.194.1.7997570
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In a phantom and in 37 patients, a simple laser guidance system for computed tomography (CT)-guided procedures used the software program of the CT scanner and a laser beam mounted on the CT gantry without need for additional software or components. The skin entry point and angulation of the target path were determined. Then the system projected the desired needle path (including compound angulation), allowing accurate needle placement in all cases, even in small lesions.
引用
收藏
页码:282 / 284
页数:3
相关论文
共 12 条
[1]   A LIGHT-GUIDANCE SYSTEM TO BE USED FOR CT-GUIDED BIOPSY [J].
FREDERICK, PR ;
BROWN, TH ;
MILLER, MH ;
BAHR, AL ;
TAYLOR, KH .
RADIOLOGY, 1985, 154 (02) :535-536
[2]   THE HOOK-WIRE TECHNIQUE FOR LOCALIZATION OF PULMONARY NODULES DURING THORACOSCOPIC RESECTION [J].
GOSSOT, D ;
MIAUX, Y ;
GUERMAZI, A ;
CELERIER, M ;
JACQUES, F .
CHEST, 1994, 105 (05) :1467-1469
[3]   PERCUTANEOUS LOCALIZATION OF PULMONARY NODULES FOR THORACOSCOPIC LUNG RESECTION [J].
MACK, MJ ;
GORDON, MJ ;
POSTMA, TW ;
BERGER, MS ;
ARONOFF, RJ ;
ACUFF, TE ;
RYAN, WH .
ANNALS OF THORACIC SURGERY, 1992, 53 (06) :1123-1124
[4]   LASER PROJECTION SYSTEM FOR RADIOTHERAPY AND CT-GUIDED BIOPSY [J].
NAGATA, Y ;
NISHIDAI, T ;
ABE, M ;
HIRAOKA, M ;
TAKAHASHI, M ;
FUJIWARA, K ;
OKAJIMA, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) :1046-1048
[5]   CT BODY STEREOTAXIS - AN AID FOR CT-GUIDED BIOPSIES [J].
ONIK, G ;
COSTELLO, P ;
COSMAN, E ;
WELLS, T ;
GOLDBERG, H ;
MOSS, A ;
KANE, R ;
CLOUSE, ME ;
HODDICK, W ;
MOORE, S ;
DEMAS, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (01) :163-168
[6]   CT-GUIDED ASPIRATIONS FOR THE BODY - COMPARISON OF HAND GUIDANCE WITH STEREOTAXIS [J].
ONIK, G ;
COSMAN, ER ;
WELLS, TH ;
GOLDBERG, HI ;
MOSS, AA ;
COSTELLO, P ;
KANE, RA ;
HODDICK, WI ;
DEMAS, B .
RADIOLOGY, 1988, 166 (02) :389-394
[7]   NEW DEVICE FOR CT-TARGETED PERCUTANEOUS PUNCTURES [J].
OZDOBA, C ;
VOIGT, K ;
NUSSLIN, F .
RADIOLOGY, 1991, 180 (02) :576-578
[8]   PERIPHERAL PULMONARY NODULES - PREOPERATIVE PERCUTANEOUS NEEDLE LOCALIZATION WITH CT GUIDANCE [J].
PLUNKETT, MB ;
PETERSON, MS ;
LANDRENEAU, RJ ;
FERSON, PF ;
POSNER, MC .
RADIOLOGY, 1992, 185 (01) :274-276
[9]   INTERVENTIONAL PROCEDURES USED FOR DIAGNOSING AND TREATING LUNG-CANCER [J].
REED, JG ;
RUBIN, SA ;
SCHNADIG, VJ .
JOURNAL OF THORACIC IMAGING, 1991, 7 (01) :48-56
[10]   A GUIDANCE DEVICE FOR CT-GUIDED PROCEDURES [J].
REYES, GD .
RADIOLOGY, 1990, 176 (03) :863-864