Concentrations of 12 selected polychlorinated biphenyl (PCB) congeners and isomers in human serum and adipose tissue after environmental and short- and long-term occupational exposures were determined. The individual congener concentrations in adipose tissue varied between <0.01 and 420 μg/kg (tri-, tetra-, penta-, hexa-, and heptachlorobiphenyls); the dominating isomers were 2,2′,4,4′,5,5′- and 2,2′,3,4,4′,5′-hexaCB, which represented approximately 90% of all PCBs in adipose tissue. Those isomers were also the most abundant in serum specimens after environmental exposure, their contribution together with the 2,2′,3,4,4′,5′,6-heptaCB was approximately 90%. After short-term as well as long-term occupational exposure, the most remarkable changes were observed in the concentrations of the tri- and tetrachlorobiphenyls. In long-term occupational exposure 2,4,4′-triCB (mean 3.15 μg/liter) and 2,4,4′,5-tetraCB (mean, 9.4 μg/liter) showed the highest concentrations, whereas after short-term exposure 2,2′,5-tri- (mean 2.04 μg/liter) and 2,3′,4,4′-tetraCB (mean 1.5 μg/liter) were most abundant. In people with only environmental exposure, the concentrations in adipose tissue of some PCB isomers were interrelated. The concentrations of the isomers 2,4,4′,5-tetraCB (IUPAC 74), 2,2′,4,4′,5,5′-hexaCB (IUPAC 153), 2,2′,3,4,4′5′-hexaCB (IUPAC 138), 2,3,3′,4,4′,5-hexaCB (IUPAC 156), 2,2′,3,4,4′,5′,6-heptaCB (IUPAC 183), and 2,2′,3,3′,4,4′,5-heptaCB (IUPAC 171) showed close correlation, the coefficients varied from 0.42 to 0.98. The correlation between the concentrations of individual PCB isomers in adipose tissue was highest for 2,4-substituted highly chlorinated isomers, i.e., isomers with longest half-times in the body. © 1991 Academic Press, Inc.
引用
收藏
页码:121 / 134
页数:14
相关论文
共 23 条
[1]   ANALYSIS OF POLYCHLORINATED-BIPHENYLS (PCB) BY GLASS-CAPILLARY GAS-CHROMATOGRAPHY - COMPOSITION OF TECHNICAL AROCLOR-PCB AND CLOPHEN-PCB MIXTURES [J].
BALLSCHMITER, K ;
ZELL, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (01) :20-31
[2]   ISOMER-SPECIFIC IDENTIFICATION OF PCB CONGENERS IN TECHNICAL MIXTURES AND ENVIRONMENTAL-SAMPLES BY HRGC-ECD AND HRGC-MSD [J].
BALLSCHMITER, K ;
SCHAFER, W ;
BUCHERT, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (03) :253-257
[3]   COMPARATIVE RATES OF ELIMINATION OF SOME INDIVIDUAL POLYCHLORINATED-BIPHENYLS FROM THE BLOOD OF PCB-POISONED PATIENTS IN TAIWAN [J].
CHEN, PH ;
LUO, ML ;
WONG, CK ;
CHEN, CJ .
FOOD AND CHEMICAL TOXICOLOGY, 1982, 20 (04) :417-425
[4]   CHARACTERIZATION OF PCB COMPONENTS IN CLOPHEN FORMULATIONS BY CAPILLARY GC MS AND GC ECD TECHNIQUES [J].
DUINKER, JC ;
HILLEBRAND, MTJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1983, 17 (08) :449-456
[5]   RECENT PCB ACCIDENTS IN FINLAND [J].
ELO, O ;
VUOJOLAHTI, P ;
JANHUNEN, H ;
RANTANEN, J .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1985, 60 (MAY) :315-319
[6]   POLYCHLORINATED BIPHENYL CONGENERS IN ADIPOSE-TISSUE LIPID AND SERUM OF PAST AND PRESENT TRANSFORMER REPAIR WORKERS AND A COMPARISON GROUP [J].
FAIT, A ;
GROSSMAN, E ;
SELF, S ;
JEFFRIES, J ;
PELLIZZARI, ED ;
EMMETT, EA .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1989, 12 (01) :42-55
[7]  
JENSEN S, 1974, Ambio, V3, P70
[8]   METABOLISM OF SYMMETRICAL HEXACHLOROBIPHENYL ISOMERS IN THE RAT [J].
KATO, S ;
MCKINNEY, JD ;
MATTHEWS, HB .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1980, 53 (03) :389-398
[9]   STRUCTURES AND CONCENTRATIONS OF MAIN COMPONENTS OF POLYCHLORINATED BIPHENYLS RETAINED IN PATIENTS WITH YUSHO [J].
KUROKI, H ;
MASUDA, Y .
CHEMOSPHERE, 1977, 6 (08) :469-474
[10]   SERUM POLYCHLORINATED-BIPHENYLS - QUANTITATION AND IDENTIFICATION OF SOURCE OF EXPOSURE BY THE SIMCA PATTERN-RECOGNITION METHOD [J].
LUOTAMO, M ;
AITIO, A ;
WOLD, S .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1988, 4 (02) :171-181